Download Print this page

Advertisement

Available languages

Available languages

Quick Links

Manual STEF Brand

Advertisement

loading

Summary of Contents for FlaktWoods STEF

  • Page 1 Manual STEF Brand...
  • Page 2: Table Of Contents

    Montering ..............8 Elkopplingar ..............9 Kopplingsschema ............11 Service ............... 12 OBS! Bryt ström till äkten ca. 2 minuter före serviceåtgärder. Installation ..............14 Electrical w iring ............15 Wiring diagram ............17 Servicing ..............18 NB. The power roof fan must be isolated from the mains power supply appr.
  • Page 3: Montering

    Fig. 1 Montering på takgenomföring BOGA 1. Montera medlevererade tätningen på takgenomföringens övre kant enligt gur 1. 2. Lyft tak äkt STEF på takgenomföringen. Vid behov använd medföljande lyftöglor. Figur 1. Observera att: – bottenplattan kommer över takgenomföringens kant. Skada inte tätningen.
  • Page 4: Elkopplingar

    4. Utför kopplingen och stäng säkerhetsbrytarens lock 5. Kontrollera säkerhetsbrytarens fuktion 6. Vid igångskörning av äkten kontrollera äkthjulets rotationsriktning FO-drift STEF tak äktar med enhastighets-trefasmotorer kan köras med frekvensomriktare. Min. drift-frekvens är 20 Hz och max. driftfrekvens 50 Hz, eventuella högre driftfrekvenser är angivna i STEF-katalog.
  • Page 5: Kopplingsschema

    Kopplingsschema Tak äkt STEF Trefasmotor, direkt elinkoppling Enhastighetsmotor, Y-koppling...
  • Page 6 ä l f Skötsel Byte av motor och äkthjul Tak äkten kräver vid normal drift inte någon skötsel. 1. Koppla bort tak äkten från elnätet med Vid drift i nedsmutsande miljö, såsom frånlufts äkt i kök, säkerhetsbrytaren. krävs rengöring av eventuella smutsavlagringar i äkthjul 2.
  • Page 7: Installation

    1. Fit the sealing strip to the top edge of the roof duct as shown in Figure 1. 2. Lift the STEF or STOF roof fan onto the roof duct. Use the lifting lugs for the larger sizes if necessary.
  • Page 8: Electrical Wiring

    Weight, kg Size STEF Frequency converter drive STEF roof fans with single speed three-phase motors can be driven with frequency converters. The min. frequency is is 20 Hz. Max. frequency is 50Hz, for possibly higher max. frequencies please refer to the STEF-catalogue.
  • Page 9: Wiring Diagram

    Wiring diagram ROOFMASTER STEF Three-phase, single speed motor star coupled...
  • Page 10 Maintenance 3. Open the back plate of the impeller and prise the impeller o the motor shaft. If necessary use an Under normal operating conditions the roof fan does not extractor. Note! It is advisable to cover the the require any other maintenance except for checking the chimney opening before dismantling the impeller so motor bearings.
  • Page 11 ROOFMASTER STEF and STOF Spare parts Spare parts Reservdelar Varaosat Varuosad Ersatzteile Reservedele Spare parts code Spare parts code Fan Impeller Motor Reservdelskod Reservdelskod Fläkthjul Motor Fan code Fan code Varaosakoodi Varaosakoodi Fläktkod Fläktkod Puhallinpyörä Moottori Puhallin Puhallin Ventilaatori kood...
  • Page 12 Spare parts ROOFMASTER STEF and STOF Spare parts Reservdelar Varaosat (savunpoisto) Varuosad Ersatzteile Reservedele Spare parts code Spare parts code Fan Impeller Motor Reservdelskod Reservdelskod Fläkthjul Motor Fan code Fan code Varaosakoodi Varaosakoodi Fläktkod Fläktkod Puhallinpyörä Moottori Puhallin Puhallin Ventilaatori kood...
  • Page 13 ROOFMASTER STEF...

This manual is also suitable for:

Roofmaster stefRoofmaster stof