All Viking Range ventilator kits are designed Society for Heating, Refrigeration and Air specifically for use with Viking Range hoods. Use of any non- Conditioning Engineers (ASHRAE), and the local Viking Range ventilator kit will void the hood warranty.
Page 4
IMPORTANT– Please Read and Follow! WA R N I N G WA R N I N G To reduce the risk of injury to persons in the event of a This appliance is not to be used by persons (including rangetop grease fire, observe the following.
Dimensions & Specifications (VBCV Wall Custom Ventilator System 36”, 42”, 48”, & 60”) Make sure the back wall of *For best results, the custom hood canopy center the unit over is flush with the cutout so the burners of the the ventilator system may cooking product be mounted as shown on...
Installing Hood Canopy (Custom Hood Canopy Cutouts Custom Hood Canopy 1) Position ventilator system inside of the custom hood canopy Built-In Ventilator and center it front to back and left to right. System 2) Bottom mounting holes fasten ventilator system to bottom of custom hood canopy with the screws provided.
Planning Information Proper installation of ducting is extremely 300 or 600 CFM important to ensure maximum performance from Roof Cap single blower any ventilation product. interior-power 7” round duct typical ductwork • All CFMs are based on tests at 0.1 static pressure: without applying static pressure, CFM would be greatly overstated.
Installation (VWH/CVWH 10”H./12”H. Wall Hoods w/Standard Ventilator) Check damper for unrestricted movement, adjust if Attach transition to damper. Seal with aluminum tape. necessary. WA R N I N G To reduce the risk of fire, electric shock, or injury to persons, observe the following: •...
Page 29
CAUTION: Secure vent hood to wall using screws CAUTION: If not using a duct cover, using screws provided, make sure top mounting screws are secured provided. Use additional mounting screws and wall anchors, if necessary. into soffit or cabinet framing. Use additional mounting screws, if necessary.
Duct Cover Option (VWH/CVWH 10”H./12”H. Wall Hoods w/Standard Ventilator) Measure distance from ceiling to canopy. Slide the duct cover in place and fasten from inside canopy using the sheet metal screws provided. Installation (VWH/CVWH 10”H./12”H. Wall Hoods w/Recirculating Kit) Remove damper and discard with transition. Turn recirculating unit upside down.
Page 31
Installation (VWH/CVWH 10”H./12”H. Wall Hoods w/Recirculating Kit) Attach with screws and lock washers provided. Attach with screws. WA R N I N G To reduce the risk of fire, electric shock, or injury to persons, observe the following: • Use this unit only in the manner intended by the manufacturer.
Page 32
Installation (con’t) (VWH/CVWH 10”H./12”H. Wall Hoods w/Recirculating Kit) Bare or Green Green Black White Black White Connect black to black, white to white, and the Replace electrical box cover. Make connection to breaker green/bare wire under the green screw. box. NOTE: Housing wiring must be properly installed for wiring to be correct when wiring unit.
Duct Cover Option (VWH/CVWH 18”H. Wall Hoods) Measure distance from ceiling to canopy. Slide the duct cover in place and fasten from inside canopy using the sheet metal screws provided. To install ventillation kit refer to ventillation kit installation instructions.
Duct Cover Option (VCWH/CVCWH Chimney Wall Hoods) Measure distance from ceiling to canopy. Tape to avoid scratching. Place duct cover top inside duct cover base and lower until Slide the duct cover in place and fasten from inside desired height is found. Mark height. Use the retaining nuts canopy using the sheet metal screws provided.
Installation (VCIH/CVCIH Island Hoods) Check framing where cutout will be. Cut appropriate size hole in ceiling. Either 7” or 10” NOTE: 200 lb. limit. depending on your specific unit and ventillator kit. Mounting options: Using duct cover with ceiling mounting bracket.
Page 37
Installation (VCIH/CVCIH Island Hoods) Run duct work down to bottom edge of duct cover/soffit Attach canopy to duct cover/soffit. Seal top of hood to and secure in place. Make sure the duct does not stick duct with aluminum tape. down past the cover. To install ventillation kit Grease Trough refer to ventillation kit...
• Name of dealer from whom purchased Clearly describe the problem that you are having. If you are unable to obtain the name of an authorized service agency, or if you continue to have service problems, contact Viking Range, LLC at 1-888-(845-4641), or write to:...
Page 40
Viking Range, LLC 111 Front Street Greenwood, Mississippi 38930 USA (662) 455-1200 For product information, call 1-888-(845-4641) or visit our web site at vikingrange.com F21287H EN (040119)