Control Cavity Access
Tools needed: Protective gloves, multi-purpose tool,
1/4" driver
• Remove decorative front.
• Remove fixed glass assembly.
• Remove glass seal plate. See Figure 4.3.
• For easier access, glass clip assemblies can be removed.
See Figure 4.5. Be careful when handling base refractory
• For access, slide out component tray. See Figure 4.4.
Note: Wires may need to be removed from clips for full
access. See Figure 4.4.
COMPONENT
TRAY RECEIVER
PRESS
TAB TO
RELEASE
UNCLIP
WIRES
GLASS SEAL PLATE
COMPONENT TRAY
WITH HEAT SHIELD
Figure 4.4 Component Tray Access
CAUTION: Be sure to reinstall the component heat shield
before firing the appliance. Components will overheat.
22
COMPONENT
TRAY
Heat & Glo • I25X-N-AU, I35X-N-AU Owner's Manual • 2547-981 Rev. B • 1/23
GLASS SEAL PLATE
BASE REFRACTORY
GLASS CLIP
ASSEMBLIES
Figure 4.5 Glass Clip Removal
GLASS
CLIP ASSEMBY
SCREW ACCESS