3.26 EXTERNAL PROBE SETTING
To activate the optional external probe, it is necessary to modify the parameter:
System definition / External probe
If the temperature probe is particular far from the indoor unit, it is possible to correct its value by modifying
System definition / External probe corr.
It is not possible to use the optional external probe kit in the case of DHW recirculation enabling.
3.27 MANUAL DRIVES
In the menu
Support / Manual drives
it is possible to manage all the main appliance loads in manual mode.
These parameters must be used in case of system troubleshooting.
To correctly activate the functions, it is necessary to set the system in "stand-by".
3.28 OUTDOOR UNIT TESTMODE FUNCTION
When test mode is used (see outdoor unit instruction booklet), the indoor unit must be set in a mode other than "Stand-by".
The alarm 183 is triggered during the test, meaning "Test mode" in progress.
3.29 OUTDOOR UNIT PUMP DOWN FUNCTION
If the pump down function is used (see outdoor unit instruction booklet) the indoor unit must be set in "Stand-by".
The function can only be activated if the appliance is not under alarm.
3.30 SUPERVISION DEVICE CONFIGURATION
The appliance can be configured so that it can be controlled by the external supervision devices such as Dominus or other types of home
automation systems (not supplied by Immergas).
For the configuration, it is necessary to modify the parameter
System definition / System supervision
It is not possible to configure both devices simultaneously.
99