Voltage limits

The 4560SLX Tape Library is capable of using any nominal ac voltage between 100
and 240 V ac power, at 50 or 60 Hz. It is capable of powering up and operating
without error from any voltage within the ranges specified:

Frequency limits

The 4560SLX Tape Library is capable of operation at either 50 Hz or 60 Hz. It will
automatically adjust for 50-60 Hz primary power operation, without requiring user
intervention or modification.

Power requirements

The 4560SLX Tape Library (with two tape drives installed) exhibits a nominal
steady state ac power consumption of 192 watts, and a maximum peak power
consumption of 240 watts.
Table 24. Current
Current
4560SLX Tape Library

Sag/Surge protection

Once powered on, the 4560SLX Tape Library will continue to operate without error
under the following conditions:
Table 25. Sag/Surge protection
Condition
100 V -20%
120 V +15%
200 V -20%
240 V -20%

Power line disturbance

Once powered on, the 4560SLX Tape Library will continue to operate without error
under the following conditions of power line disturbances:
Table 26. Power line disturbance
Disturbance
PULSE:
1.2 ms rise - 50 ms decay
8.0 ms rise - 20 s decay
RING: 0.5 ms @ 100 KHz
Get other manuals https://www.bkmanuals.com
1.6 - 1.0 A (120 V ac - 240 V ac)
Period
2 seconds
1 second
2 seconds
2 seconds
Period
High
Low
High
Low
Limit
1.0 KV, Max
300 A, Max
1.0 KV, Max
200 A, Max