Table 19. Shock specifications (transit/storage)
Transit/storage (packed - no damage)
Peak Acceleration
Duration
Waveshape
Application
Table 20. Shock specifications (physical drop test)
Physical drop test (packaged - no damage)
Drop Test Distance
Application

Vibration

The following tables provide operating, non-operating, and transit/storage
vibration specifications for the 4560SLX Tape Library.
Table 21. Vibration specifications (operating)
Operating (within spec - no damage)
Frequency Range
Peak Acceleration
Waveshape
Application
Table 22. Vibration specifications (non-operating)
Non-operating (unpacked - no damage)
Frequency Range
Peak Acceleration
Waveshape
Application
Table 23. Vibration specifications (transit/storage)
Transit/storage (packed - no damage)
Frequency Range
Peak Acceleration
Waveshape
Application

Primary power

This section provides information on voltage and frequency limits, power
requirements, sag/surge protection, and power line disturbance for the 4560SLX
Tape Library.
94
4560SLX Tape Library: User's Guide
Get other manuals https://www.bkmanuals.com
30 G's
30 ms
1/2 sine pulses
X,Y,Z axes, repeat 3 times
12 in. (30.5 cm)
Per ISTA (1 time)
5-1000-5 Hz
.25 G's
Sinusoidal, 1 octave/min
X,Y, Z axes, 2 sweeps pers
5-1000-5 Hz
1.0 G's
Sinusoidal, 1 octave/min
X,Y, Z axes, 2 sweeps pers
5-1000-5 Hz
2.0 G's
Sinusoidal, 1 octave/min
X,Y, Z axes, 2 sweeps pers