vento expert (Duo) a30/50/85/100(c1)-1 (Pro3) W v.2 www.blaubergventilatoren.de CONTENTS Safety requirements ..................................2 Purpose ........................................ 4 Delivery set ......................................4 Designation key ....................................4 Technical data ....................................5 Design and operating principle ............................6 Mounting and set-up .................................. 9 Connection to power mains ..............................12 Technical maintenance ................................
Page 3
vento expert (Duo) a30/50/85/100(c1)-1 (Pro3) W v.2 www.blaubergventilatoren.de The appliance may adversely affect the safe operation of appliances burning gas or other fuels (including those in other rooms) due to back flow of combustion gases. These gases can potentially result in carbon monoxide poisoning. After installation of the unit the operation of flued gas appliances should be tested by a competent person to ensure that back flow of combustion gases does not occur.
vento expert (Duo) a30/50/85/100(c1)-1 (Pro3) W v.2 www.blaubergventilatoren.de PURPOSE The ventilator is designed to ensure continuous mechanical air exchange in flats, cottages, hotels, cafés and other domestic and public premises. The ventilator is equipped with a regenerator that enables supply of fresh filtered air heated by means of extract air heat energy recovery.
vento expert (Duo) a30/50/85/100(c1)-1 (Pro3) W v.2 www.blaubergventilatoren.de TECHNICAL DATA The temperature in the room where the indoor unit of the ventilator is installed must be in the range from +1 ˚C to +40 ˚C with relative air humidity up to 80 % (no condensation build-up). If the conditions of use of the ventilator are outside the specified limits, turn off the ventilator.
vento expert (Duo) a30/50/85/100(c1)-1 (Pro3) W v.2 www.blaubergventilatoren.de The technical data of the specific model are indicated on the label on the ventilator casing. DESIGN AND OPERATING PRINCIPLE The ventilator consists of an indoor unit with a decorative front panel, a cartridge, an air duct with a sound absorbing layer and an outer ventilation hood.
Page 7
vento expert (Duo) a30/50/85/100(c1)-1 (Pro3) W v.2 www.blaubergventilatoren.de OPERATING LOGIC OF THE AUTOMATIC SHUTTERS FOR VENTO Expert A30/50/85/100(C1)-1 W V.2 The indoor unit of the VENTO Expert A30/50/85/100(C1)-1 W V.2 ventilators is equipped with automatic shutters. During the ventilator operation the automatic shutters are opened and let the air flow freely through the ventilator. The automatic shutters are closed for 2 minutes at the ventilator shut down.
Page 8
(“Party mode”) (4 hours by default). If necessary, in the “Schedule of the Blauberg Home mobile application” section, you can set different speeds of the ventilator at different time intervals by day of the week. For the weekly schedule to work correctly, you must set the current date and time correctly in the “Date and time”...
vento expert (Duo) a30/50/85/100(c1)-1 (Pro3) W v.2 www.blaubergventilatoren.de MOUNTING AND SET-UP READ THE USER'S MANUAL BEFORE INSTALLING THE UNIT DO NOT BLOCK THE AIR DUCT OF THE INSTALLED VENTILATOR WITH DUST ACCUMULATING MATERIALS, SUCH AS CURTAINS, CLOTH SHUTTERS, ETC. AS IT PREVENTS AIR CIRCULATION IN THE ROOM. 1.
Page 10
vento expert (Duo) a30/50/85/100(c1)-1 (Pro3) W v.2 www.blaubergventilatoren.de 3. Fasten the supplied mounting template to the indoor wall using the adhesive tape. The large opening in the template must be coaxial with the air duct. For aligning the template with respect to the horizon line it is recommended to use a builder’s level. Then mark the fastening holes for installation of the supplied dowels and drill the holes to a required depth.
Page 11
vento expert (Duo) a30/50/85/100(c1)-1 (Pro3) W v.2 www.blaubergventilatoren.de 7. Insert the cartridge in the air duct as shown below. During mounting make sure the pointer is directed upwards. Then fix the cable with a clamp and connect the socket connector to the control board. The pointer must be directed upwards Lay the cables under the clamp...
vento expert (Duo) a30/50/85/100(c1)-1 (Pro3) W v.2 www.blaubergventilatoren.de CONNECTION TO POWER MAINS POWER OFF THE POWER SUPPLY PRIOR TO ANY OPERATIONS WITH THE UNIT. THE UNIT MUST BE CONNECTED TO POWER SUPPLY BY A QUALIFIED ELECTRICIAN. THE RATED ELECTRICAL PARAMETERS OF THE UNIT ARE GIVEN ON THE MANUFACTURER’S LABEL.
Page 13
vento expert (Duo) a30/50/85/100(c1)-1 (Pro3) W v.2 www.blaubergventilatoren.de PRE-SETTING OF THE VENTILATOR Prior to operating the ventilator set it up using the DIP switch. It is located on the controller circuit board. To access the DIP switch, take off the front panel of the indoor unit and uplift the rubber plug that covers the switch. DIP switch and USB connector under the cover...
Page 14
vento expert (Duo) a30/50/85/100(c1)-1 (Pro3) W v.2 www.blaubergventilatoren.de The figure below shows the control buttons on the indoor unit and the remote control with a brief description of their function. Speed/Standby Turning ventilator on/off The speed selection sequence is follows: I-II-III-Standby. Speed selection Regeneration mode The fan rotation direction changes to...
Page 15
vento expert (Duo) a30/50/85/100(c1)-1 (Pro3) W v.2 www.blaubergventilatoren.de VENTILATOR CONTROL WITH THE BUTTONS ON THE INDOOR UNIT The table below shows the buttons and indicators on the indoor unit of the ventilator with a detailed description of their purpose and functionality.
Page 16
Press any speed setting key to deactivate the timer or press the timer control button once again. REMOTE CONTROL OF THE VENTILATOR WITH A BLAUBERG HOME APP Download the Blauberg Home application and install it on the mobile device. Blauberg Home – App Store Blauberg Home –...
Page 17
vento expert (Duo) a30/50/85/100(c1)-1 (Pro3) W v.2 www.blaubergventilatoren.de WIRELESS CONNECTION OF SEVERAL VENTILATION UNITS The ventilators can be combined into a group in which one ventilator acts as a Master device and the others are connected to it as Slaves. If the ventilator is a Master unit, Slave units and mobile devices connect to it via Wi-Fi.
Page 18
vento expert (Duo) a30/50/85/100(c1)-1 (Pro3) W v.2 www.blaubergventilatoren.de VENTILATOR WIRELESS CONNECTION DIAGRAMS Wiring diagram 1 Connection of up to 8 Slave units or mobile devices to the Master unit with its own wireless Master with a Wi-Fi access point access point. If eight Slave ventilators are connected to a Master ventilator with a Wi-Fi access point you cannot connect a mobile device!
Page 19
Set the DIP switches on each ventilator to the position that corresponds to its role in the group (see “DIP switch position”). • Then configure the Wi-Fi settings of the Master ventilator by following the instructions in the Blauberg Home mobile app. •...
vento expert (Duo) a30/50/85/100(c1)-1 (Pro3) W v.2 www.blaubergventilatoren.de TECHNICAL MAINTENANCE DISCONNECT THE UNIT FROM POWER SUPPLY BEFORE ANY MAINTENANCE OPERATIONS! MAKE SURE THE UNIT IS DISCONNECTED FROM POWER MAINS BEFORE REMOVING THE PROTECTION Maintenance of the ventilator means regular cleaning of the ventilator surfaces of dust and cleaning and replacement of the filters. To enable access to the main units, follow the procedure described below.
Page 21
vento expert (Duo) a30/50/85/100(c1)-1 (Pro3) W v.2 www.blaubergventilatoren.de 3. Pull the cord to remove the cartridge from the air duct. VENTO Expert VENTO Expert Duo Clean the filters as often as required, but at least 3 times a year. • Upon elapse of the set time period (factory setting 90 days) the filter replacement indicator (Filter) starts glowing.
vento expert (Duo) a30/50/85/100(c1)-1 (Pro3) W v.2 www.blaubergventilatoren.de POSSIBLE FAULTS AND TROUBLESHOOTING Problem Possible reasons Troubleshooting Make sure the power supply line is connected No power supply. correctly, otherwise troubleshoot the connection When switching on the error. ventilator the fan does not Turn the ventilator off.
vento expert (Duo) a30/50/85/100(c1)-1 (Pro3) W v.2 www.blaubergventilatoren.de MANUFACTURER’S WARRANTY The product is in compliance with EU norms and standards on low voltage guidelines and electromagnetic compatibility. We hereby declare that the product complies with the provisions of Electromagnetic Compatibility (EMC) Directive 2014/30/EU of the European Parliament and of the Council, Low Voltage Directive (LVD) 2014/35/EU of the European Parliament and of the Council and CE-marking Council Directive 93/68/EEC.
Page 24
vento expert (Duo) a30/50/85/100(c1)-1 (Pro3) W v.2 www.blaubergventilatoren.de...
Page 25
vento expert (Duo) a30/50/85/100(c1)-1 (Pro3) W v.2 www.blaubergventilatoren.de...
Page 26
vento expert (Duo) a30/50/85/100(c1)-1 (Pro3) W v.2 www.blaubergventilatoren.de...
vento expert (Duo) a30/50/85/100(c1)-1 (Pro3) W v.2 www.blaubergventilatoren.de CERTIFICATE OF ACCEPTANCE Unit Type Single-room reversible energy recovery ventilator Model Serial Number Manufacture Date Quality Inspector’s Stamp SELLER INFORMATION Seller Address Phone Number E-mail Purchase Date This is to certify acceptance of the complete unit delivery with the user’s manual. The warranty terms are acknowledged and accepted.