100D20 / Generator Sets
With the current limit switch in the ON position, and the system supplying DC load current only,
typically for engine starting, the DC current can be limited. And external current limit dial
graduated in load current is provided and the desired maximum DC current that can be supplied
to the aircraft can be set at any current between 300 and 2000 amperes.
For other detailed information on this voltage regulator, refer to regulator manual OM-2020 in
Chapter 6.
1. Resistor (1000 Ohms, 25 Watts)
2. Regulator Rheostat
3. Cable Length Compensation Rheostat
4. Cable Size Compensation Rheostat
5. On-Off Switch, Line Drop Compensation
6. Line Drop Compensation, Chassis Assy.
7. Receptacle Connector
8. Damping Circuit Gain Potentiometer
9. Receptacle Connector
10. Damping Circuit Rate Potentiometer
March 31/94 Revised
11. Receptacle Connector
12. Fuse (5 amp)
13. Fuseholder
14. Receptacle Connector
15. Sensing & Preamplifier Chassis
16. High-Phase Sensing Board Assembly
17. Reactor, Regulator
18. Chassis
19. Terminal Board
Voltage Regulator (Part No. 430391C)
Figure 12
Assembly