6

Storage conditions

6.1

General safety

The e-tron system trainer should be stored in a dry, cool room. The storage temperature
must be between +10 °C and + 40 °C. When the e-tron system trainer is not being used
for voltage measurements, the plug must be pulled out and the power supply
disconnected. The plug of the power cable must not lie on the floor. The e-tron system
trainer should not be exposed to direct sunlight or strong vibrations. Protect the tron
system trainer from dust or dirt. The product must be secured against rolling away.
7

Set-up conditions

7.1

Safety

-
The e-tron system trainer must be secured against rolling away.
-
Only properly instructed persons may work on the trainer. This must be clearly
indicated by signs. (see safety marking 2.6.)
-
The e-tron system trainer must not be set up next to liquids or damp rooms (e.g.,
bathrooms).
-
The working space around the system trainer must be respected
7.2

Total space requirement

-
Movement space at the workstations: 220 cm x 190 cm
-
An AC household socket near the trainer is required for the voltage supply. The socket
must be easily accessible. The connection cable must not be laid under carpets or
similar.
7.3

Dimensions and weights

-
Required floor space: 120 cm x 90 cm
-
Weight: approx. 90 kg
7.4

Foundation and flooring

-
Level, horizontal, solid floor
-
The e-tron system trainer must not be exposed to vibrations
7.5

Ambient conditions

-
Temperature range (°C): +10 °C to +35 °C
-
Relative humidity (%): 70 % non-condensing
-
Altitude above sea level (m): 1000
-
Cleanliness (cleanroom or cleanroom class): Cleanliness level SaS1 (clean room
according to VDA 19.2)
-
The e-tron system trainer should not be placed or stored in areas where there is a risk
of fire or in damp and wet areas
-
The mains supply must be protected by a residual current circuit breaker (RCD) with a
tripping current <= 30mA