Mounting
4.1.3.4 Radial run-out tolerance of the motor shaft
Nominal
motor shaft
diameter
[mm]
0 — ≤ 10
> 10 — ≤ 30
> 30 — ≤ 50
> 50 — ≤ 80
4.1.3.5 Axial run-out and coaxiality tolerance of the motor flange
Flange size/
Square
measure
[mm]
0 — ≤ 40
> 40 — ≤ 100
> 100 — ≤ 230
> 230 — ≤ 450
4.2
Attaching the motor to the gearbox by means of the drive pinion
(direct motor mounting)
Information
If the gearbox is prepared for mounting a motor by means of a drive pinion directly
connected to the motor shaft, please refer to the mounting instructions supplied
with the gearbox for detailed information on mounting the motor to the gearbox or
connecting the drive pinion to the motor shaft.
Radial run-out tolerance [mm]
PLE, PLQE, PLPE, PLHE, PLFE, PFHE,
WPLE, WPLQE, WPLPE, WPLFE,
WPLHE, NGV
0.03
0.04
0.05
0.06
Axial runout and coaxiality tolerance [mm]
PLE, PLQE, PLPE, PLHE, PLFE, PFHE,
WPLE, WPLQE, WPLPE, WPLFE,
WPLHE, NGV
0.06
0.08
0.10
0.13
PSBN, PSN, PLN, PSFN, PLFN,
PSBN, PSN, PLN, PSFN, PLFN,
14
WPLN, WPSFN, WGN
0.015
0.020
0.025
0.030
WPLN, WPSFN, WGN
0.03
0.04
0.05
0.06