Soleus Air KFHHP-22 Technical & Service Manual page 14

13seer dc inverter 24k
Hide thumbs Also See for KFHHP-22:
Table of Contents

Advertisement

D14
Meaning
blink 6 times
Unit closing down for
min.frequency
blink 7 times
Unit closing down for
PFC protection
blink 8 times
Unit closing down for
compressor overloading
D17
Meaning
blink 1 time
too low DC input voltage
blink 2 times
too high DC voltage
blink 3 times
AC current protection
blink 4 times
IPM abnormality
blink 5 times
reserved built-in PFC
protection
blink 6 times
start-up failure
blink 7 times
phase-losing or out of
control
blink 8 times
first PFC protection ;then
module protection
D15
blink 6 times
blink 7 times
blink 8 times
blink 9 times
D18
when no short-circuit in
computer monitor port
short-circuit in
blink
computer monitor port
blink
-14-
frequency of current 12 A lasting for 2 minutes
frequency limiting or demultiplying for rate of
frequency variation out of control
frequency limiting or demultiplying of compressor
frequency limiting or demultiplying for over temp.of
IPM module
On
receiving or sending indoor data
off
receiving or sending indoor data finished
normal communication between main borad and
driving board
not
abnormal communication between main board and
driving board
Meaning
current
Meaning