Switch
Suggested
position
battery type
PzS tubular
plate traction
6
batteries or
OPzS batteries
Lithium Iron
Phosphate
7
(LiFePo4)
batteries
* The top value is for 12V systems, the middle for 24V systems and the bottom for 48V systems.
** Equalize is by default disabled. To enable see chapter
A binary LED code helps determining the position of the rotary switch. After changing the position of the rotary switch, the LEDs
will blink during 4 seconds as indicated in below table. Thereafter, normal indication resumes, as described in the LEDs section.
Switch position
0
1
2
3
4
5
6
7
5.1.3. Settings via the SmartSolar Control display
The SmartSolar Control display can be used to configure solar charger settings. For information how to do this see the
SmartSolar Control display
manual.
5.1.4. Settings via MPPT Control display
The MPPT Control display can be used to configure solar charger settings, with the exception of advanced settings such as RX
and TX port settings. For information how to do this see the
Although the MPPT Control display can connect to the solar charger, consider using a SmartSolar control
display instead.
Page 17
MPPT solar charger manual
Float
Absorption
voltage*
voltage* (V)
(V)
15.3
13.8
30.6
27.6
61.2
55.2
14.2
13.5
28.4
27.0
56.8
54
Bulk LED
Absorption LED
1
1
0
0
0
1
0
1
1
0
1
0
1
1
1
1
The SmartSolar display
MPPT Control display
The MPPT Control display
Equalize**
Equalize**
nominal
voltage* (V)
current
percentage
17.1
34.2
25%
68.4
n/a
n/a
Battery settings [18]
Float LED
Blinking frequency
1
1
0
1
0
1
0
1
manual.
Configuration and settings
Temperature
compensation
factor* (mV/°C)
-16
-32
-64
0
0
0
Fast
Slow
Slow
Slow
Slow
Slow
Slow
Slow