Actuator Coding; Working Principle And Diagnostic Function; Mode Of Operation Of The Safety Outputs; Diagnostic-Leds - schmersal RSS 36-D-ST5 Manual

Electronic safety-sensor
Hide thumbs Also See for RSS 36-D-ST5:
Table of Contents

Advertisement

Connecting cables with coupling (female) IP69K, M12, 8-pole - 8 x 0,21 mm²
Cable length
5,0 m
5,0 m, angled
10,0 m
15,0 m
Connecting cables (PUR) with coupling (female) IP67 / IP69, M12, 5-pole - 5 x 0.34 mm² to EN 60947-5-2
Cable length
5.0 m
10.0 m
15.0 m

6 Actuator coding

Safety sensors with standard coding are ready to use upon delivery.
Individually coded safety sensors and actuators will require the following "teach-in" procedure:
1. Energise the safety sensor.
2. Introduce the actuator in the detection range. The teach-in procedure is signalled at the safety sensor, red
LED on, yellow LED flashes (1 Hz).
3. After 10 seconds, brief yellow cyclic flashes (3 Hz) request the switch-off of the operating voltage of the
solenoid interlock. (If the voltage is not switched off within 5 minutes, the safety sensor cancels the "teach-
in" procedure and signals a false actuator by 5 red flashes).
4. Once the operating voltage is switched back on, the actuator must be detected once more in order to
activate the actuator code that has been taught in. In this way, the activated code is definitively saved!
For ordering suffix -I1, the executed allocation of safety switchgear and actuator is irreversible.
For ordering suffix -I2, the "teach-in" procedure for a new actuator can be repeated an unlimited number of times.
When a new actuator is taught, the code, which was applicable until that moment, becomes invalid. Subsequent to
that, an enabling inhibit will be active for ten minutes, thus providing for an increased protection against tampering.
The green LED will flash until the expiration of the time of the enabling inhibit and the detection of the new
actuator. In case of power failure during the lapse of time, the 10-minutes tampering protection time will restart.

7 Working principle and diagnostic function

7.1 Mode of operation of the safety outputs

The safety outputs can be integrated into the safety circuit of the control system.
The opening of a safety guard, i.e. the actuator is removed out of the active zone of the sensor, will immediately
disable the safety outputs of the sensor.

7.2 Diagnostic-LEDs

Ordering code
101210560
101210561
103001389
103014823
Ordering code
103010816
103010818
103010820