schmersal RSS260 AS Operating Instructions Manual

schmersal RSS260 AS Operating Instructions Manual

Advertisement

Quick Links

Operating instructions
Safety sensor
Operating instructions. . . . . . . . . . . . .pages 1 to 8
EN
Original
Content
1
About this document
1.1 Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.2 Target group: authorised qualified personnel. . . . . . . . . . . . . . . . . .1
1.3 Explanation of the symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.4 Appropriate use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.5 General safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
1.6 Warning about misuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
1.7 Exclusion of liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2
2.1 Ordering code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.2 Special versions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.4 Purpose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.5 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.6 Safety classification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
3
3.1 General mounting instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
3.2 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
3.3 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
3.4 Actuating directions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
3.5 Switching distance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
3.6 Adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
4
4.1 General information for electrical connection. . . . . . . . . . . . . . . . . .5
5
5.1 Programming the slave address . . . . . . . . . . . . . . . . . . . . . . . . . . .5
5.2 Configuration of the safety monitor . . . . . . . . . . . . . . . . . . . . . . . . .5
5.4 Actuator teaching / actuator detection . . . . . . . . . . . . . . . . . . . . . . .5
6
6.1 LED indications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
6.2 Error . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
6.3 Diagnostic information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
6.4 Diagnostic signal periphery error . . . . . . . . . . . . . . . . . . . . . . . . . . .6
6.5 Read-out of the parameter port . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
7
7.1 Functional testing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
7.2 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
8
8.1 Disassembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
8.2 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
9
EU Declaration of conformity
1. About this document

1.1 Function

This operating instructions manual provides all the information you
need for the mounting, set-up and commissioning to ensure the safe
operation and disassembly of the safety switchgear. The operating
instructions must be available in a legible condition and a complete
version in the vicinity of the device.

1.2 Target group: authorised qualified personnel

All operations described in this operating instructions manual must
be carried out by trained specialist personnel, authorised by the plant
operator only.
Please make sure that you have read and understood these operating
instructions and that you know all applicable legislations regarding
occupational safety and accident prevention prior to installation and
putting the component into operation.
The machine builder must carefully select the harmonised standards
to be complied with as well as other technical specifications for the
selection, mounting and integration of the components.

1.3 Explanation of the symbols used

Information, hint, note:
This symbol is used for identifying useful additional information.
Caution: Failure to comply with this warning notice could
lead to failures or malfunctions.
Warning: Failure to comply with this warning notice could
lead to physical injury and/or damage to the machine.

1.4 Appropriate use

The products described in these operating instructions are developed to
execute safety-related functions as part of an entire plant or machine. It
is the responsibility of the manufacturer of a machine or plant to ensure
the correct functionality of the entire machine or plant.
The safety switchgear must be exclusively used in accordance with
the versions listed below or for the applications authorised by the
manufacturer. Detailed information regarding the range of applications
can be found in the chapter "Product description".
EN
RSS260 AS
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RSS260 AS and is the answer not in the manual?

Questions and answers

Summary of Contents for schmersal RSS260 AS

  • Page 1: Table Of Contents

    Operating instructions Safety sensor RSS260 AS Diagnostic 6.1 LED indications ........6 6.2 Error .
  • Page 2: General Safety Instructions

    2.3 Comprehensive quality insurance to 2006/42/EC The user must observe the safety instructions in this operating instructions Schmersal is a certified company to appendix X of the Machinery manual, labelled with the caution or warning symbol above, the country- Directive. As a result, Schmersal is entitled to autonomously conduct...
  • Page 3: Safety Classification

    Operating instructions Safety sensor RSS260 AS Ambient conditions The active areas of the sensor and the actuator have to face each Ambient temperature: −25 °C ... +60 °C other. The safety sensor must only be used within the assured Storage and transport temperature: −25 °C ...
  • Page 4: Dimensions

    Operating instructions Safety sensor RSS260 AS 3.3 Dimensions 3.4 Actuating directions All measurements in mm. Actuation from front Safety sensor RSS260-…-ST-AS Actuation from side 39. 2 47. 5 Safety sensor RSS260-...-LSTM12-AS Lateral actuation only from the shown sensor side 3.5 Switching distance The side allows for a maximum height misalignment (X) of sensor Actuator RST260-1 / RST260-1-AD01 …...
  • Page 5: Adjustment

    5.2 Configuration of the safety monitor The correct functionality of both safety channels must be checked by The RSS260 AS can be configured in the ASIMON configuration means of the connected safety-monitoring module. software with the following monitoring devices (also refer to the ASIMON manual).
  • Page 6: Diagnostic

    / device error 6.2 Error Errors, which no longer guarantee the safe functionality of the RSS260 AS electromagnetic interlock, cause the safety outputs to be switched off and are signaled through a flashing pattern of the red LED. (see table 2).
  • Page 7: Set-Up And Maintenance

    Operating instructions Safety sensor RSS260 AS 7. Set-up and maintenance 8. Disassembly and disposal 7.1 Functional testing 8.1 Disassembly The safety function of the safety components must be tested. The The safety switchgear must be disassembled in a de-energised following conditions must be previously checked and met: condition only.
  • Page 8 Philip Schmersal Managing Director The currently valid declaration of conformity can be downloaded from the internet at www.schmersal.net. K. A. Schmersal GmbH & Co. KG Möddinghofe 30, D - 42279 Wuppertal Postfach 24 02 63, D - 42232 Wuppertal Phone:...

Table of Contents