Advertisement

Quick Links

Operating instructions
Safety sensor
Operating instructions. . . . . . . . . . . .pages 1 to 10
EN
Original
Content
1
About this document
1.1 Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.2 Target group: authorised qualified personnel. . . . . . . . . . . . . . . . . .1
1.3 Explanation of the symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.4 Appropriate use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.5 General safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.6 Warning about misuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
1.7 Exclusion of liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2
2.1 Ordering code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.2 Special versions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.4 Destination and use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.5 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.6 Safety classification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
3
3.1 General mounting instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
3.2 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
3.3 Actuating directions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
3.4 Switching distance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
3.5 Adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
4
4.1 General information for electrical connection. . . . . . . . . . . . . . . . . .5
4.2 Serial diagnostic -SD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
5
5.1 Mode of operation of the safety outputs. . . . . . . . . . . . . . . . . . . . . .5
5.2 Coding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
6
6.1 Operating principle of the diagnostic LED's . . . . . . . . . . . . . . . . . . .6
6.3 Safety-sensors with serial diagnostic function . . . . . . . . . . . . . . . . .7
7
7.1 Functional testing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
7.2 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
8
8.1 Disassembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
8.2 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
9
9.2 Wiring examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
10 EU Declaration of conformity
1. About this document

1.1 Function

This operating instructions manual provides all the information you
need for the mounting, set-up and commissioning to ensure the safe
operation and disassembly of the safety switchgear. The operating
instructions must be available in a legible condition and a complete
version in the vicinity of the device.

1.2 Target group: authorised qualified personnel

All operations described in this operating instructions manual must
be carried out by trained specialist personnel, authorised by the plant
operator only.
Please make sure that you have read and understood these operating
instructions and that you know all applicable legislations regarding
occupational safety and accident prevention prior to installation and
putting the component into operation.
The machine builder must carefully select the harmonised standards
to be complied with as well as other technical specifications for the
selection, mounting and integration of the components.

1.3 Explanation of the symbols used

Information, hint, note:
This symbol is used for identifying useful additional information.
Caution: Failure to comply with this warning notice could
lead to failures or malfunctions.
Warning: Failure to comply with this warning notice could
lead to physical injury and/or damage to the machine.

1.4 Appropriate use

The products described in these operating instructions are developed to
execute safety-related functions as part of an entire plant or machine. It
is the responsibility of the manufacturer of a machine or plant to ensure
the correct functionality of the entire machine or plant.
The safety switchgear must be exclusively used in accordance with
the versions listed below or for the applications authorised by the
manufacturer. Detailed information regarding the range of applications
can be found in the chapter "Product description".

1.5 General safety instructions

The user must observe the safety instructions in this operating
instructions manual, labelled with the caution or warning symbol above,
the country-specific installation standards as well as all prevailing safety
regulations and accident prevention rules.
Further technical information can be found in the Schmersal
catalogues or in the online catalogue on the Internet:
www.schmersal.net.
EN
RSS260
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RSS260 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for schmersal RSS260

  • Page 1: Table Of Contents

    5.2 Coding ..........5 Further technical information can be found in the Schmersal...
  • Page 2: Warning About Misuse

    8 mm 2.3 Comprehensive quality insurance to 2006/42/EC - with sideways approach: 4 mm Schmersal is a certified company to appendix X of the Machinery Assured switch-off distance s 18 mm Directive. As a result, Schmersal is entitled to autonomously con- Hysteresis: <...
  • Page 3: Safety Classification

    Operating instructions Safety sensor RSS260 Accessories (to be ordered separately) Required rated short-circuit current: 100 A Rated insulation voltage U 32 V Rated impulse withstand voltage U 800 V Kit tamper-proof screws Residual current I < 0.5 mA • 4 x M4x20 incl. washers, ordering code 103006158...
  • Page 4: Dimensions

    The side allows for a maximum height misalignment (X) of sensor and actuator of ± 8 mm (e.g. mounting tolerance or due to guard door Safety sensor RSS260-...-ST sagging). The axial misalignment (Y) is max. ± 18 mm. 39. 2 47.
  • Page 5: Electrical Connection

    Information for the selection of suitable safety-monitoring After fault rectification, the error message is reset by opening and modules can be found in the Schmersal catalogues or in the re-closing the corresponding safety guard. The safety outputs enable online catalogue on the Internet: www.schmersal.net.
  • Page 6: Diagnostic Functions

    Operating instructions Safety sensor RSS260 6. Diagnostic functions 6.2 Operating principle of the electronic diagnostic output A diagnostic output additionally indicates the operating condition 6.1 Operating principle of the diagnostic LED's (refer to table 1). These signals can be used in a downstream control.
  • Page 7: Safety-Sensors With Serial Diagnostic Function

    PLC. The necessary documentation for the integration of the SD- safety outputs are only deleted upon the next release, as the fault Gateway is available for download at www.schmersal.com. rectification cannot be detected sooner. The response data and the diagnostic data are automatically and...
  • Page 8: Set-Up And Maintenance

    Damaged or defective components must be replaced. 9. Appendix 9.1 Wiring configuration and connector accessories Function safety switchgear Pin configuration of the Colour code of the Schmersal poss. Colour codes for more connector connector to DIN 47100 commercially available with conventional...
  • Page 9: Wiring Examples

    Operating instructions Safety sensor RSS260 9.2 Wiring examples The application examples shown are suggestions. They however do not release the user from carefully checking whether the switchgear and its set-up are suitable for the individual application. Wiring example 1: Series-wiring of the RSS 260 with conventional diagnostic output The voltage is supplied to both safety inputs of the last safety sensor of the chain (considered from the safety-monitoring module).
  • Page 10 Philip Schmersal Managing Director The currently valid declaration of conformity can be downloaded from the internet at www.schmersal.net. K. A. Schmersal GmbH & Co. KG Möddinghofe 30, D - 42279 Wuppertal Postfach 24 02 63, D - 42232 Wuppertal Phone:...

Table of Contents