1
About this document
1.1 Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.2 Target group: authorised qualified personnel. . . . . . . . . . . . . . . . . .1
1.3 Explanation of the symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.4 Appropriate use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.5 General safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.6 Warning about misuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
1.7 Exclusion of liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2
2.1 Ordering code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.2 Special versions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.4 Purpose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.5 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.6 Safety classification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
3
3.1 General mounting instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
3.2 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
3.3 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
3.4 Switch distance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
3.5 Adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
4
4.1 General information for electrical connection. . . . . . . . . . . . . . . . . .5
5
5.1 Programming the slave address . . . . . . . . . . . . . . . . . . . . . . . . . . .5
5.2 Configuration of the safety monitor . . . . . . . . . . . . . . . . . . . . . . . . .5
5.4 Actuator teaching / actuator detection . . . . . . . . . . . . . . . . . . . . . . .5
6
6.1 LED indications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
6.2 Error . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
6.3 Diagnostic information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
6.4 Diagnostic signal periphery error . . . . . . . . . . . . . . . . . . . . . . . . . . .6
6.5 Read-out of the parameter port . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
7
7.1 Functional testing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
7.2 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
8
8.1 Disassembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
8.2 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
9
EU Declaration of conformity
1. About this document

1.1 Function

This operating instructions manual provides all the information you
need for the mounting, set-up and commissioning to ensure the safe
operation and disassembly of the safety switchgear. The operating
instructions must be available in a legible condition and a complete
version in the vicinity of the device.

1.2 Target group: authorised qualified personnel

All operations described in this operating instructions manual must
be carried out by trained specialist personnel, authorised by the plant
operator only.
Please make sure that you have read and understood these operating
instructions and that you know all applicable legislations regarding
occupational safety and accident prevention prior to installation and
putting the component into operation.
The machine builder must carefully select the harmonised standards
to be complied with as well as other technical specifications for the
selection, mounting and integration of the components.

1.3 Explanation of the symbols used

Information, hint, note:
This symbol is used for identifying useful additional information.
Caution: Failure to comply with this warning notice could
lead to failures or malfunctions.
Warning: Failure to comply with this warning notice could
lead to physical injury and/or damage to the machine.

1.4 Appropriate use

The products described in these operating instructions are developed to
execute safety-related functions as part of an entire plant or machine. It
is the responsibility of the manufacturer of a machine or plant to ensure
the correct functionality of the entire machine or plant.
The safety switchgear must be exclusively used in accordance with
the versions listed below or for the applications authorised by the
manufacturer. Detailed information regarding the range of applications
can be found in the chapter "Product description".

1.5 General safety instructions

The user must observe the safety instructions in this operating instructions
manual, labelled with the caution or warning symbol above, the country-
specific installation standards as well as all prevailing safety regulations and
accident prevention rules.
Further technical information can be found in the Schmersal
catalogues or in the online catalogue on the Internet:
www.schmersal.net.
The information contained in this operating instructions manual is
provided without liability and is subject to technical modifications.
There are no residual risks, provided that the safety instructions as well
as the instructions regarding mounting, commissioning, operation and
maintenance are observed.
EN
RSS36-AS
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RSS36-ST-AS and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for schmersal RSS36-ST-AS

  • Page 1: Table Of Contents

    Functions and configuration Further technical information can be found in the Schmersal 5.1 Programming the slave address ......5 catalogues or in the online catalogue on the Internet: 5.2 Configuration of the safety monitor .
  • Page 2: Warning About Misuse

    20 mm 2.3 Comprehensive quality insurance to 2006/42/EC - Hysteresis: < 2.0 mm Schmersal is a certified company to appendix X of the Machinery - Repeat accuracy R: < 0.5 mm Directive. As a result, Schmersal is entitled to autonomously conduct Latching force (R): approx.
  • Page 3: Safety Classification

    Operating instructions Safety sensor RSS36-AS 3. Mounting AS-i inputs: - Channel 1: Data bits DI 0/DI 1 = dynamic code transmission - Channel 2: Data bits DI 2/DI 3 = dynamic code transmission 3.1 General mounting instructions Databits condition static 0 or dynamic code transmission Please observe the relevant requirements of the standards AS-i Outputs:...
  • Page 4: Dimensions

    Transverse misalignment S [mm] 5 10 15 Y [mm] Height misalignment S [mm] Alternative suitable actuators with different design: refer to www.schmersal.net. 3.4 Switch distance 5 10 15 20 24 Switching distances to IEC 60947-5-3: X [mm] Typical switching distance s...
  • Page 5: Electrical Connection

    Operating instructions Safety sensor RSS36-AS 4. Electrical connection 5.4 Actuator teaching / actuator detection Safety sensors with standard coding are ready to use upon delivery. 4.1 General information for electrical connection Individually coded safety sensors and actuators will require the following "teach-in"...
  • Page 6: Diagnostic

    Operating instructions Safety sensor RSS36-AS 6. Diagnostic 6.2 Error Errors, which no longer guarantee the safe functionality of the RSS36 6.1 LED indications AS electromagnetic interlock, cause the safety outputs to be switched The LED's have the following meaning (to EN 62026-2): off and are signaled through a flashing pattern of the red LED.
  • Page 7: Set-Up And Maintenance

    Operating instructions Safety sensor RSS36-AS 7. Set-up and maintenance 7.1 Functional testing The safety function of the safety components must be tested. The following conditions must be previously checked and met: 1. Fitting of the sensor and the actuator. 2. Fitting and integrity of the power cable. 3.
  • Page 8 Safety sensor RSS36-AS 9. EU Declaration of conformity EU Declaration of conformity Original K.A. Schmersal GmbH & Co. KG Möddinghofe 30 42279 Wuppertal Germany Internet: www.schmersal.com We hereby certify that the hereafter described components both in their basic design and construction conform to the applicable European Directives.