Download Print this page
Oriental motor 5RK60GU-AWMJ Operating Manual
Oriental motor 5RK60GU-AWMJ Operating Manual

Oriental motor 5RK60GU-AWMJ Operating Manual

Electromagnetic brake motors

Advertisement

Quick Links

Thank you for purchasing ORIENTAL MOTOR products.
Please read this operating manual thoroughly before
installing and operating the motor, and always keep
the manual where it is readily accessible.
<Table of contents>
1. Precautions...............................................Page 1
2. Checking the package contents ...............Page 1
3. Regulations and standards .......................Page 2
4. Installation ................................................Page 2
1. Precautions
1.1
Precautions for Installation
• Do not use in a place where there is flammable gas and/or corrosive gas.
• When installing the motor into your equipment, ensure that the motor lead wires are fixed and do not move.
In addition, do not apply any pressure to these lead wires.
• The motor is Class І equipment. Install the motor so as to avoid contact with hands, or ground it to prevent the risk of electric shock.
• The motor housing must be mounted with a screw and spring washer to the ground point of the equipment.
• Installation must be performed by a qualified installer.
1.2
Precautions for Operation
• The Motor case temperature can exceed 70°C (depending on operation conditions). In case motor is
accessible during operation, please attach the following warning label so that it is clearly visible.
• Always turn off the power to the motor before conducting checks or performing work on the motor.
Thermally protected motors will restart automatically when motor temperature falls bellow a certain level.
• Do not use the electromagnetic brake of the motor as a safety brake.
In the event the overheat protection device (thermal protector) is triggered, the load will not be held in position.
A safety device should be provided separately.
2. Checking the package contents
2.1
Checking the contents
Make sure that you have received all of the items listed below.
If an accessory is missing or damaged,contact the nearest ORIENTAL MOTOR office.
• Motor ..........................1
• Capacitor ....................1 (for only single-phase motors )
2.2
Checking the product name and motor-capacitor combination
This product comes in a combined set consisting of a motor and a capacitor. When the product first arrives, check the name plates to confirm that
you have received the correct motor and capacitor combination.
„ 100V/110V/115V type
Model
5RK60GU-AWMJ
5RK60GU-AWMU
5RK90GU-AWMJ
5RK90GU-AWMU
Motor model
Capacitor Model
CH250CFAUL2
5RK60GU-AWM
CH200CFAUL2
CH350CFAUL
5RK90GU-AWM
CH300CFAUL2
World K Series
Electromagnetic Brake Motors
OPERATING MANUAL
5.Connection and Operation............................... Page 4
6. Time Rating .................................................... Page 5
7. Locked rotor burnout protection...................... Page 5
8. Troubleshooting .............................................. Page 6
• Capacitor cap ..........................1 (for only single-phase motors )
• This operating manual ............1
„ 200V/220V/230V type
Model
Motor model
5RK60GU-CWMJ
5RK60GU-CWM
5RK60GU-CWME
5RK90GU-CWMJ
5RK90GU-CWM
5RK90GU-CWME
5IK60GU-SWM
5IK60GU-SWM
5IK90GU-SWM
5IK90GU-SWM
HM-9097-12
Warning label
Capacitor Model
CH60BFAUL
CH50BFAUL
CH80BFAUL
CH70BFAUL
1

Advertisement

loading

Summary of Contents for Oriental motor 5RK60GU-AWMJ

  • Page 1 2. Checking the package contents Checking the contents Make sure that you have received all of the items listed below. If an accessory is missing or damaged,contact the nearest ORIENTAL MOTOR office. • Motor ......1 • Capacitor cap ......1 (for only single-phase motors ) •...
  • Page 2: Regulations And Standards

    3. Regulations and standards Check on the Oriental Motor Website for the regulations and standards. „ UL Standards, CSA Standards This product is recognized by UL under the UL and CSA Standards. „ CE Marking This product is affixed the CE Marking under the Low Voltage Directive.
  • Page 3 Mounting the motor 1) Pinion shaft motor Drill holes in the mounting plate that match the screws and the motor’s dimensions. Attach the motor and gearhead using the screws supplied with the gearhead Motor (gearhead sold separately). Gearhead Fasten the screws supplied with the gearhead to the mounting plate. Attach so Mounting that no gaps are left between the motor flange surface and the gearhead pilot Screws provided...
  • Page 4: Connection And Operation

    SW1 emits sparks when turned on and off. In order to protect the relay contacts, CR circuit ( ) must be connected. Ro=5~200Ω Co=0.1~0.2μF 250WV Option of the ORIENTAL MOTOR’s surge absorber is available. Optional product name EPCR1201-2 (sold separately) Specification No. of...
  • Page 5: Operation

    Operation Note: -Make sure that the motor case temperature does not exceed 90°C (194°F) during motor operation. Operating the motor above 90°C (194°F) will shorten the life of the coil and the ball bearings. Motor case temperature can be measured by fastening a thermometer to the motor’s surface, or with thermo-tape. Thermal Class: 130 (B) -Be sure to use the capacitor that comes standard with your motor.
  • Page 6: Troubleshooting

    Oriental Motor Co., Ltd. • © Copyright ORIENTAL MOTOR CO., LTD. 2008 Published in November 2022 • Please contact your nearest Oriental Motor o ce for further information. Technical Support Tel:800-468-3982 Singapore Korea 8:30am EST to 5:00pm PST (M-F)

This manual is also suitable for:

World k series5rk60gu-awmu5rk90gu-awmj5rk90gu-awmu5rk60gu-cwmj5rk60gu-cwme ... Show all