Serial Cable Installation; Cable Installation - Cardinal RD3 Installation And Technical Manual

Remote display
Table of Contents

Advertisement

Cable Installation

1. Remove the 12 screws securing the front panel to the main housing.
2. Referring to Figure No. 5, choose a gland connector for the serial cable, loosen it, and
remove the rubber plug.
3. Slip the single cable through the gland connector and into the enclosure.
4. Remove approximately 3 inches of the outer insulation jacket from the cable then remove
1/4 inch of insulation from each of the wires.
5. Referring to the labels on the circuit board) for terminal connections, connect each of the
wires to terminal block P4. Refer to Figure No. 9 for the terminal block location
6. To terminate a wire, use a small flat-blade screwdriver and press down on the release bar
for the terminal. Insert the wire into the terminal opening. Remove the screwdriver,
allowing the release bar to return to its original position, locking the wire in place.
7. Repeat the procedure until all wires are in place.
8. After all, terminations have been made, remove any excess cable from the enclosure, and
securely tighten the cable gland connector. Finger-tighten only! DO NOT USE TOOLS!
6
8200-M063-O1 Rev C  RD3 Installation and Technical Manual

SERIAL CABLE INSTALLATION

 AC Power
Figure No. 5
Serial In/Out 