Venting Fireplace - Rear - Empire Comfort Systems DVP42DP31-2 Installation Instructions And Owner's Manual

Direct vent gas fireplace heater
Table of Contents

Advertisement

To Use the Vent Graph (Figure 31)
1. Determine the height of the center of the
horizontal vent pipe. Using this dimension on
the Sidewall Vent Graph, locate the point it
intersects with the slanted graph line.
2. From the point of this intersection, draw a vertical
line to the bottom of the graph.
3. Select the indicated dimension, and position the
unit in accordance with same.
EXAMPLE A:
If the vertical dimension from the floor of the unit
is 12 feet, 4 inches the horizontal run to the outer
wall flange must not exceed 12 feet, 3 inches.
EXAMPLE B:
If the vertical dimension from the floor of the unit is
6 feet, 9 inches the horizontal run to the outer wall
flange must not exceed 6 feet, 6 inches.
Special Note: For each 45 degree elbow installed
in the horizontal run, the length of the horizontal
run MUST be reduced by 18" (45cm). This does
not apply if the 45 degree elbows are installed on
the vertical part of the vent system. Reduce 3' for
every 90° elbow.
Example: According to the chart the maximum
horizontal vent length is 20' and if two 45 degree
elbows are required in the horizontal vent it must
be reduced to 17'.
The maximum number of 45 degree elbows
permitted per side wall installation is two (2).
These elbows can be installed in either the vertical
or horizontal run.
Page 20

VENTING FIREPLACE - REAR

REAR HORIZONTAL
VENT CONNECTION
Venting Graph (Dimensions in Feet)
REAR EXIT - VERTICAL AND HORIZONTAL TERMINATION
(DIMENSIONS IN FEET)
40
39
38
37
36
35
34
33
32
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
1
2
3
4
5
6
7
HORIZONTAL RUN
Acceptable vertical and horizontal vent run.
Unacceptable vertical and horizontal vent run.
A
B
9
8
10 11 12 13 14 15 16
Figure 31
17
18
19 20
26928-0-0110

Advertisement

Table of Contents
loading

Table of Contents