VENTING FIREPLACE - TOP (continued)
(305mm)
SEE CHART FOR
PERMISSIBLE
"H" AND "V"
DIMENSIONS
MINIMUM
HOLE LOCATION DIMENSIONS FOR
THROUGH THE WALL HORIZONTAL INSTALLATIONS
WITH 90 DEGREE ELBOW OFF TOP OF FIREPLACE
FIREPLACE
HARD ELBOW DIMENSIONS
SERIES
"A"
DVP42DP
43-1/2"
(1105mm)
FIREPLACE
FLEX PIPE 90 DEGREE BEND
SERIES
"A"
DVP42DP
46"
(1143mm)
Positioning the Fireplace
Determine the exact position of the appliance so the direct vent
termination will be centered (if possible) between two (2) studs. This
will avoid any extra framing. All vent kit pipes should be assembled
on the unit after the unit is moved into the final position.
Cutting the Hole (Figure 25)
After the fireplace has been positioned in its permanent location,
the hole through the exterior wall of the house can be cut. This hole
must be 12" (305mm) high x 10" (254mm) wide with its center line
determined by the amount of vertical rise and horizontal run of the
termination. See Figure 25. When locating the hole it must be noted
that the bottom of the cap must be 12" (305mm) above the ground
level, and top of the cap must be no less than 18" (457mm) below
a combustible projection, and no closer than 9" (229mm) to any
wall running parallel to vent termination. See Figure 26.
Page 18
10"
(254mm)
C
12"
B
V
H
C
B
A
CENTER OF ELBOW
STRAIGHT OUT
(MINIMUM)
Figure 25
"B"
"C"
5"
7"
(127mm)
(178mm)
"B"
"C"
5"
7"
(127mm)
(178mm)
Figure 26
Figure 27
26928-0-0110
minimum