1.2 Principle of operation. AWZ 110 is a stabilized transformer PSU with high factor of voltage stabilization. Mains supply ~230V is reduced by a transformer and then rectified by the system of rectifiers and a low pass filter. DC output voltage is gained in the linear regulator and it is adjusted according to the PSU operation type (charging phase and battery maintenance).
Page 4
AWZ110 AC pins: Z1, Z2 - configuration of time lag for AC failure indication , Z2= time lag T= 0s , Z2= time lag T= 5min , Z2= time lag T= 1h , Z2= time lag T= 6h ...
AWZ110 Table 2. Elements of the PSU (see Fig. 3.) Element no. Description Isolation transformer Pcb of the PSU (Tab. 1, Fig. 2) fuse in the battery circuit (230V/AC) MAIN [4], [5] L-N 230V/AC power supply connector, PE protection connector Battery connectors +BAT = red, - BAT = black Fig.
Page 6
AWZ110 200% ÷ 250% of PSU power - current limitation and/or fuse Short-circuit protection SCP damage in the battery circuit (fuse-element replacement required) 110% ÷ 150% (@25ºC÷65ºC) of PSU power - limitation by Overload protection OLP the PTC resettable fuse, manual restart (disconnection of...
AWZ110 Fig. 4. Uwy=f(Io) diagram. 2. Installation 2.1 Requirements The buffer PSU is to be mounted by a qualified installer, holding relevant permits and licenses (applicable and required for a given country) for 230V/AC interference and low-voltage installations. The unit should be mounted in confined spaces, in accordance with the 1st environmental class, with normal relative humidity (RH=90% maximum, without condensing) and temperature from +5°C to +40°C.
Page 8
AWZ110 - AW output indicating failure During normal PSU operation, the AW technical output is connected to ground. If a failure occurs, the output is cut from ground. 6. During battery-assisted operation, it is possible to determine time necessary for battery disconnection by the Z3, Z4 pins when the voltage at its terminals drops below 10V.
AWZ110 3. Operating status indication. The power supply unit features LED and acoustic status indication. PSU status can be remote-controlled by two technical outputs. 3.1 LED indication RED LED: twinkling – indicates failure status (Tab. 7) GREEN LED: illuminating –...
AWZ110 3.3 Technical outputs. The PSU is equipped with two independent indication outputs, OC type (open collector). They enable transmitting the information about no AC power status and system faults. Fig. 6. Electrical diagram of OC outputs. AW – failure output: an OC type output indicating a PSU failure. In normal state (during correct operation) the output connected to the ground, in case of the failure –...
AWZ110 4.4 Battery charging current limitation The PSU has a system that automatically limits the battery charging current: Ibat = 0,4A max. – the CHARGE jumper on 4.5 Battery-assisted operation – standby time To keep the standby time, the current drawn from the PSU during batter-assisted operation should be limited.
Page 12
GENERAL WARRANTY CONDITIONS 1. Pulsar K. Bogusz Sp.j. (the manufacturer) grants a five-year warranty for the equipment, , counted from the device’s production date. 2. The warranty includes free-of-charge repair or replacement with an appropriate equivalent (the selection is at the manufacturer’s discretion) if the malfunction is due to the manufacturer, includes manufacturing or material defects,...