Replace Power Supply Unit (Psu) - Synology NAS FS3410 Hardware Installation Manual

Table of Contents

Advertisement

4 Find the malfunctioning fan. Lift up the fan to remove it.
5 Prepare a new fan and slide it into FS3410. Make sure that the fan is aligned properly.

Replace Power Supply Unit (PSU)

If a PSU or its fan malfunctions, please follow the steps below to replace the malfunctioning PSU.
1 Unplug the power cord from the PSU that is to be replaced.
Note:
By pressing the Beep Off button, you can silence the long beep when it sounds.
2 Remove the malfunctioning PSU:
1 On the rear panel, push the lever of the PSU inward as shown.
2 Pull the PSU out of your FS3410.
3 Prepare a new PSU. Insert it into the empty slot until you hear a click.
21 Chapter 3: System Maintenance