5 Prepare a new fan, and slide it into the RackStation. Make sure the fan is aligned properly as illustrated below.
6 Put back the fan cover you removed in step 2.
Replace Redundant PSU on RackStation
If a PSU
1
or its fan malfunctions, please see the instructions below to replace the malfunctioning PSU.
1 Unplug the power cord from the PSU to be replaced.
Note:
By pressing the Beep Off button, you can silence the long beeping sound when you hear it.
2 Push the lever of the PSU at the back panel in the indicated direction.
3 Pull out the PSU from the RackStation.
4 Prepare a new PSU, and push it back to the slot until you hear a click.
1
Only for RS2418RP+.