Mounting the unit............... 11 Daikin website (publicly accessible). 5.4.1 Precautions when mounting the unit......11 ▪ The full set of latest technical data is available on the Daikin 5.4.2 To prepare the cold room..........11 Business Portal (authentication required). 5.4.3 To prepare the unit............
Direct contact with skin or eyes refrigerant is required. can lead to serious injuries and burns. Before handling and installing this unit, read the service manual "Systems DANGER using R290 refrigerant" available on the regional Daikin website. NOTICE ...
MUST be as such that the current-carrying wires are tautened before the earth wire is in case the power supply is pulled loose from the stress relief. Installation manual LMSEY1A09/13 + LMSEY2A19/25 Daikin LMS 4P728170-1 – 2023.03...
▪ A forklift can be used for transport as long as the unit remains on Particular requirements for commercial its pallet. refrigerating appliances and ice-makers with an incorporated or remote refrigerant unit or motor-compressor. EN 12100 Risk assessment LMSEY1A09/13 + LMSEY2A19/25 Installation manual Daikin LMS 4P728170-1 – 2023.03...
4 27] for the weight of the unit. "10 Technical 2 Cut the straps (c). 3 Remove the cardboard protection (e) from the condenser. 4 Remove the plastic wrap from around the unit. Installation manual LMSEY1A09/13 + LMSEY2A19/25 Daikin LMS 4P728170-1 – 2023.03...
In this document, LMSEY1A13AVM01 is shown in the instructions, Unit evaporator unless there is a need to treat both models separately. LMSEY2A19AYE01 + LMSEY2A25AYE01 System layout LMSEY1A09AVM01 + LMSEY1A13AVM01 Unit condenser Unit evaporator Cold room roof Insulation (accessory) Unit condenser...
The primary unit performs all monitoring and control functions. INFORMATION The system can be connected to the internet through the router The door heater accessory is only necessary for low (optional). temperature applications. Installation manual LMSEY1A09/13 + LMSEY2A19/25 Daikin LMS 4P728170-1 – 2023.03...
If an anteroom room is not provided, an air curtain or a vinyl curtain door is open, limits the in- and outgoing airflow. can be used to limit the inflow of outside air. LMSEY1A09/13 + LMSEY2A19/25 Installation manual Daikin LMS 4P728170-1 – 2023.03...
Choose the correct saw in function of the wall thickness of the cold room. Make sure the blade is long enough to cut through the entire wall panel. 5‒1 For LMSEY1A09+13 Installation manual LMSEY1A09/13 + LMSEY2A19/25 Daikin LMS 4P728170-1 – 2023.03...
(a) and back plate (b) can easily be damaged. CAUTION Use a lifting table and straps that can bear the weight, if necessary balance with additional weight. data" [ 4 27] for the weight of the unit. "10 Technical LMSEY1A09/13 + LMSEY2A19/25 Installation manual Daikin LMS 4P728170-1 – 2023.03...
Page 12
(a) and so in to the back panel of the unit condenser. 3 Tighten the screws (d) to the point that the spring washer (c) is flattened. Installation manual LMSEY1A09/13 + LMSEY2A19/25 Daikin LMS 4P728170-1 – 2023.03...
The top screws will be installed after the unit is sealed and the roof is unit" [ 4 14]. installed. See "5.4.6 To seal the 5.4.5 To reinstall the drain pan 1 Install the drain pan assembly (d): LMSEY1A09/13 + LMSEY2A19/25 Installation manual Daikin LMS 4P728170-1 – 2023.03...
A number to identify the phases is printed on the surface of the wire insulation. The meaning of the numbers is the following: 1=L1, 2=L2, 3=L3, 4=neutral. Installation manual LMSEY1A09/13 + LMSEY2A19/25 Daikin LMS 4P728170-1 – 2023.03...
▪ for LMSEY1A09+13AVM01: to the fieldbus connector (J5) of the primary unit. ▪ for LMSEY2A19+25AYE01: to X6M of the primary unit with a shielded cable. Unit condenser Wire (5 m long) Wire label Door microswitch LMSEY1A09/13 + LMSEY2A19/25 Installation manual Daikin LMS 4P728170-1 – 2023.03...
0.3 A. into the unit. 4 Connect the wiring to the lamp. 2 Guide the cable towards the cable gland, and into the unit. Secure the cable into the cable gland. Installation manual LMSEY1A09/13 + LMSEY2A19/25 Daikin LMS 4P728170-1 – 2023.03...
Alarm (light or sound) CAUTION Do NOT push or place redundant cable length into the unit. 4 Connect the router (b) wiring to the BMS connector (c) of the controller (a). LMSEY1A09/13 + LMSEY2A19/25 Installation manual Daikin LMS 4P728170-1 – 2023.03...
Daikin Installer). However, some of the parameters can also be set via the user interface. The Daikin Installer app is required to configure the controller, set up parameters or check trends and information. From a mobile device (smartphone, tablet), via BLE (Bluetooth Low Result: The display shows the message “Loc”.
Defrost terminated after maximum time signal: ● ▪ 0: disabled ▪ 1: enabled Delay time for high and low temp. alarms (AH, AL) ● ● High temp. alarm bypass time for door open ● ● LMSEY1A09/13 + LMSEY2A19/25 Installation manual Daikin LMS 4P728170-1 – 2023.03...
Page 20
39.2 Auxiliary evaporator end defrost temperature (read by Sd2) -50/ °C/°F ● 39.2 Eco mode status: ▪ 0 OFF ▪ 1 ON ESP_1 Enable shared parameters for secondary unit 1 ● Installation manual LMSEY1A09/13 + LMSEY2A19/25 Daikin LMS 4P728170-1 – 2023.03...
Page 21
Time light stays on after closing the door ● Date of the first intervention dd/mm/ yyyy Date of the second intervention dd/mm/ yyyy Date of the third intervention dd/mm/ yyyy LMSEY1A09/13 + LMSEY2A19/25 Installation manual Daikin LMS 4P728170-1 – 2023.03...
Page 22
Automatic night-time set point variation ∆°C/°F ● Night temperature regulation differential 99.9 ∆°C/°F ● Temperature control differential 0.1/ 99.9/ ∆°C/°F ● ● 179.2 Reset alarms ● Maximum monitored probe value (read only) °C/°F ● Installation manual LMSEY1A09/13 + LMSEY2A19/25 Daikin LMS 4P728170-1 – 2023.03...
Page 23
● tE2-d End timespan 2 – day 0:00:00 0:00:00 23:59:59 ● tE2-time End time datatype 2 0:00:00 0:00:00 23:59:59 ● tE3-d End timespan 3 – day 0:00:00 0:00:00 23:59:59 ● LMSEY1A09/13 + LMSEY2A19/25 Installation manual Daikin LMS 4P728170-1 – 2023.03...
Bluetooth using the 6.5.1 To set the adress of the units Daikin Installer app. 3 On the primary unit controller, set: To set the parameters for multiple units, the address of the controllers MUST be sequential: ▪...
"nrt" with the following values: dS_4 with the following values: ▪ 0: The relative controller regulates through the probe connected to ▪ 0: No synchronisation performed. itself. LMSEY1A09/13 + LMSEY2A19/25 Installation manual Daikin LMS 4P728170-1 – 2023.03...
"dI" parameter user manual). setting. Therefore the "dI" parameter must always be set. Switch off the unit. About the alarms To check and reset alarms (error codes), see the operation manual. Installation manual LMSEY1A09/13 + LMSEY2A19/25 Daikin LMS 4P728170-1 – 2023.03...
▪ A subset of the latest technical data is available on the regional Line aux fuse Daikin website (publicly accessible). Neutral aux fuse ▪ The full set of latest technical data is available on the Daikin User interface Business Portal (authentication required). HMI cable...
Page 28
Three phase filter Main line fuse Main neutral fuse Line aux fuse User interface HMI cable User interface cable connection HPS1 High pressure switch 1 HPS2 High pressure switch 1 Installation manual LMSEY1A09/13 + LMSEY2A19/25 Daikin LMS 4P728170-1 – 2023.03...
Th6(B) Thermistor (evaporator outlet) Th7(B) Thermistor (condenser) 10.3 Weight Model Type Weight LMSEY1A09AVM01 52 kg LMSEY1A13AVM01 LMSEY2A19AYE01 83.5 kg LMSEY2A25AYE01 WARNING Make sure that the forklift, or any other lifting device used, can bear the weight of the unit. Refrigerant charge pipe...
Page 30
Optional equipment Equipment made or approved by Daikin that can be combined with the product according to the instructions in the accompanying documentation. Field supply Equipment NOT made by Daikin that can be combined with product according instructions accompanying documentation.
Page 32
4P728170-1 0000000N 4P728170-1 2023.03 Verantwortung für Energie und Umwelt...