Flue System Typical Installation - andrews ECOflo EC96/380 Installation And Service Manual

High efficiency condensing storage water heaters for natural gas
Table of Contents

Advertisement

R
S
F
P
Fig. 7
Terminal Positions with Minimum Distance (mm)
A
Directly below an opening, air brick, opening window etc.
B
Above an opening, air brick, opening window etc
C
Horizontal to an opening, air brick, opening window etc.
D
Below a gutter or sanitary pipework
E
Below the eaves
F
Below a balcony or carport roof
G Above ground, roof or balcony level
H
From vertical drain/soil pipework
J
From an internal or external corner
K
From a surface or boundary facing the terminal
L
Vertically from a terminal on the same wall
M Horizontally from a terminal on the same wall
N
From a terminal facing the terminal
P
From an opening in a carport (e.g. door, windows) into the building
Q Above roof
R
From a vertical structure on a roof
S
Above flat roof
* If > 2500mm from an obstruction if < 2500 refer to IGE/UP/10
30
R
M
L
G
Likely flue positions requiring
a flue terminal guard
3.28.7 Flue Systems Typical Installation
D
C
E
G
B
F
A
A
H
J
J
G
Q
S
K, N
EC96/380
Model
2500mm
762mm
762mm
200mm
200
mm
Not permitted
300mm
150mm
762mm
1518mm
2500mm
600mm
2433mm
Not permitted
400mm*
2500mm
400mm*
Installation
3