Navien NPE-180A2 Installation Manual page 88

Npe condensing water heaters
Hide thumbs Also See for NPE-180A2:
Table of Contents

Advertisement

3. Reinstall the gasket and maintenance port
cover, and then fix them with a set screw.
If condensate comes out the port when
Note
opened, check for proper drainage or
any blockage.
4. Visually inspect the maintenance port to ensure
that the gasket is properly installed between the
maintenance port and the maintenance port
cover.
WARNING
Carbon Monoxide Hazard
To prevent serious injury or death, ALWAYS
check the gasket is properly installed under
the maintenance port cover after checking
the operating condition of the damper plate
through the maintenance port.
Harmful exhaust gas may leak if the gasket is
not installed, or if it is not installed properly.
88
Installing a Common Vent System
Gasket

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Npe-210a2Npe-240a2Npe-180s2Npe-210s2Npe-240s2Npe-150s2

Table of Contents