Navien NPE-180A2 Installation Manual page 48

Npe condensing water heaters
Hide thumbs Also See for NPE-180A2:
Table of Contents

Advertisement

Ref Description
Vertical clearance to ventilated
soffit located above the terminal
within a horizontal distance of
D
2 ft (61 cm) from the center line
of the terminal.
Clearance to unventilated soffit
E
Clearance to outside corner
F
Clearance to inside corner
G
Clearance to each side of center
line extended above meter/
H
regulator assembly
Clearance to service regulator
I
vent outlet
Clearance to nonmechanical air
supply inlet to building or the
J
combustion air inlet to any other
appliance
Clearance to a mechanical air
K
supply inlet
Clearance above paved sidewalk
or paved driveway located on
L
public property
Clearance under veranda, porch
M
deck, or balcony
* Suggested clearances by the manufacturer. If the clearances required by local codes are different from those from the table above,
the greater clearance should apply.
1 The minimum distance from adjacent public walkways, adjacent buildings, openable windows, and building openings shall not be
less than those values specified in the National Fuel Gas Code, ANSI Z223.1/NFPA 54, and/or the Natural Gas and Propane Installation
Code, CSA B149.1;
2 Information on preventing blockage by snow; and
3 Information on protecting building materials from degradation by flue gases.
† A vent shall not terminate directly above a sidewalk or paved driveway that is located between two single family dwellings and
serves both dwellings.
‡ Permitted only if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the floor.
In accordance with the current CSA B149.1, Natural Gas and Propane Installation Code
Note
In accordance with the current ANSI Z223.1/NFPA 54, National Fuel Gas Code.
If locally adopted installation codes specify clearances different than those illustrated, then the
most stringent clearance shall prevail.
48
Installing the Water Heater
Canadian installations
1
3 ft (91 cm)*
3 ft (91 cm)*
2 ft (61 cm)*
12 in. (30 cm)*
3 ft (91 cm) within a height of
15 ft (4.6 m)
3 ft (91 cm)
36 in. (91 cm) for appliances
>100,000 Btuh (30 kW)
6 ft (1.83 m)
7 ft (2.13 m)
12 in. (30 cm)
US installations
2
3 ft (91 cm)*
3 ft (91 cm)*
2 ft (61 cm)*
12 in. (30 cm)*
3 ft (91 cm) within a height of
15 ft (4.6 m)*
3 ft (91 cm)*
12 in. (30 cm) for appliances >
50,000 Btuh (15 kW)
3 ft (91 cm) above if within 10 ft
(3 m) horizontally
7 ft (2.13 m) for mechanical draft
systems (Category I appliances).
Vents for Category II and IV
appliances cannot be located
above public walkways or other
areas where condensate or vapor
can cause a nuisance or hazard*
12 in. (30 cm) - open on 3 sides*