Navien NPE-180A2 Installation Manual page 55

Npe condensing water heaters
Hide thumbs Also See for NPE-180A2:
Table of Contents

Advertisement

The following stainless steel (AL29-4C) vent
components can be used as terminations:
Duravent FasNSeal® (Certified to UL1738 and
ULCS636)
FSELB9003 (3" 90° Elbow)
FSELB8803 (3" 88° Elbow)
FSELB4503 (3" 45° Elbow)
FST3 (3" Tee)
FSBS3 (3" Birdscreen)
Heat Fab Saf-T Vent® EZ Seal (Certified to
UL1738 and ULCS636)
9314(LR) or 9314TERM (3 " 90° Elbow)
9311 (3" 45° Elbow)
9390TEE (3" Tee)
9392 (3" Birdscreen)
Z-Flex® Z Vent (Certified to UL1738 and ULCS636)
2SVEEWCF0390 (90° Elbow)
2SVEEWCF0345 (45° Elbow)
2SVSTTF03 (3" Tee)
Only the termination models listed
Note
above are approved for use with this
appliance.
Only terminations of the same
manufacturer as the vent system
must be used.
Refer to the vent manufacturer's
instructions for detailed installation
procedures and guidelines.
Indoor Water Heater Installation
Venting Examples
WARNING
Fire and Explosion Hazard
To prevent death, serious injury or property
damage:
ALWAYS make sure to follow the provided
clearance requirements.
Failure to do so may result in circulating
exhaust gas and cause dangerous operation
of the water heater.
The following are some possible indoor venting
options:
Two-Pipe Sidewall Venting
[Interior View]
1 2 " ( 3
Exhaust Gas
[Exterior View]
Intake Air
Exhaust Gas
i n .
m ) m
0 0 m
Intake Air
Installing the Water Heater
55