7.5.1.3 Setting the Application
1. From the Installer Menu, select 3. Application
Settings.
2. Press the Up button (
(
) to switch between the parameters or to
increase or decrease setting values. Press the OK
button (
) to select a parameter or to confirm
after making changes.
Category
Item
1. NaviLink
1. NaviLink
Connection
2. AHU
1. AHU
Communication
Communication
100 Operating the Water Heater
) or the Down button
Description
Turn on or turn off
the remote control
capabilities via
the Navi-Link
connection.
Setting range:
●
Enable, Disable
Default: Disable
●
Enable or
disable the AHU
link function
communication.
Setting range:
●
Enable, Disable
Default: Disable
●
Category
Item
1. AHU Burn
Delay Time
2. AHU Pump
Post Purge Time
3. Air Handler Unit
3. AHU Outdoor
Low Temp
Air handler settings are only
Note
applicable when using the H2Air
accessory.
Description
Set the pump run
delay time when
AHU and AHU
pump control are
ON.
Setting range:
●
0 - 120 Sec
Default: 30 Sec
●
Set the pump
post-purge
time when AHU
and AHU pump
control are ON.
Setting range:
●
0 - 120 Sec
Default: 30 Sec
●
Set the outdoor
low temperature
when AHU and
the outdoor reset
function are ON.
Setting range:
●
–4 °F (–20 °C)
- 59 °F (15 °C)
or [Outdoor
High Temp
Set-point–9 °F
(5 °C)]
Default: 14 °F
●
(–10 °C)