FOR THE PLUMBER

Water Inlet
Air Cooled Models: Connect a water supply of
cold, potable water. Use 3/8" O.D. copper tubing
to connect to the 3/8" male flare at the back of the
cabinet. Install a hand valve near the machine to
control the water supply.
Water Cooled
Connections
Water Inlet
3/8" Flare
Hand Shut
Off Valve
Connect To
Cold Water
Filter, Field
Installed
(Optional)
Water Cooled Models: Connect a separate 3/8"
O.D. copper line with a separate hand valve to the
3/8" FPT condenser inlet at the back of the cabinet.
The water pressure to all lines must always be
above 20 psig, and below 80 psig.
Drains
CONFORM TO ALL APPLICABLE CODES
NME1254 & FME1504
Air Cooled Models: Connect a drain tube to the
3/4" FPT drain fitting at the back of the cabinet. It
is a gravity drain, and 1/4 inch per foot fall is an
acceptable pitch for the drain tubing. There should
be a vent at the highest point of the drain line, and
the ideal drain receptacle would be a trapped and
vented floor drain.
Water Cooled Models: In addition to the above
mentioned drain, a separate condenser drain must
be installed. Connect it to the 1/2" condenser drain
connection at the back of the cabinet.
Storage Bin: A separate gravity type drain needs
to be run, similar to the air cooled drain.
Insulation of this drain line is recommended.
January 2000
Page 5
Use only 3/4" rigid tubing.
Ice Machine
Bin Drain
3/4" FPT
Drain
3/4" FPT