NME1254 & FME1504

AUGER MAINTENANCE

In some areas, the water supply to the Ice Machine
will contain a high concentration of minerals, and
that will result in an evaporator and auger
becoming coated with mineral scale, requiring a
more frequent removal than twice per year. If in
doubt about the condition of the evaporator and
auger, remove the auger so the parts can be
inspected.
Note: Water filters can filter out suspended solids,
but not dissolved solids. "Soft" water may not be
the complete answer. Check with a water
treatment specialist regarding water treatment.
For more information on removal of these
parts, see REMOVAL AND REPLACEMENT.
Turn off the water supply.
1. To remove the auger, remove the front and top
panels.
2. Push back bail clamp holding ice chute cover to
ice chute, and remove cover.
3. Unscrew and remove ice sweep.
4. Remove ice chute from evaporator.
5. Remove 4 allen screws holding breaker to
evaporator.
6. Drain the evaporator by lowering and uncapping
the evaporator drain hose.
7. Pull up to remove auger.
After the auger has been removed, allow the auger
to dry: if the auger is not bright and shiny, it must
be cleaned.
Clean the auger and evaporator as required. DO
NOT HONE THE EVAPORATOR.
8. Replace the water seal.
9. Reverse to reassemble.
Hazardous Moving
Parts.
Rotating auger can cause
personal injury.
Disconnect electrical
power before beginning
maintenance.
Handle auger with care, it has sharp edges.
June 2002
Page 18
ALLEN HEAD
SCREWS
BREAKER &
BEARING &
AUGER
ASSEMBLY