FOR THE PLUMBER

CONFORM TO ALL APPLICABLE CODES
Water Inlet
The recommended water supply is
WATER INLET
3/8" MALE
cold water. Use 3/8" O.D. copper
FLARE
tubing, connect to the 3/8" male
flare at the back of the cabinet.
Install a hand valve near the
machine to control the water
FIELD
SUPPLIED
supply.
WATER FILTER
Drains
HAND SHUT
There is one 3/4" FPT drain at the
OFF VALVE
VENT
back of the cabinet, the drain line
CONNECT TO
ICEMAKER
is of the gravity type, and 1/4 inch
COLD WATER
DRAIN,
per foot fall is an acceptable pitch
3/4" FPT
for the drain tubing. There should
be a vent at the highest point of
the drain line, and the ideal drain
receptacle would be a trapped and
vented floor drain. Use only 3/4"
rigid tubing.
Storage Bin: A separate gravity
type drain needs to be run.
Insulation of this drain line is
recommended.
VENT BIN DRAIN
3/4" FPT
FLOOR DRAIN