SSI Sensor / Scheduler Interface -
Part# C156.273
SSI+ Sensor / Scheduler Interface with Glare Control -
Part# C156.304

Advertisement

loading
Need help?

Need help?

Do you have a question about the IntelliFlex I/O SSI and is the answer not in the manual?

Questions and answers

Summary of Contents for Draper IntelliFlex I/O SSI

  • Page 1 SSI Sensor / Scheduler Interface - Part# C156.273 SSI+ Sensor / Scheduler Interface with Glare Control - Part# C156.304...
  • Page 2 INSTRUCTION PROGRAMMING Overview - SSI and SSI+ Comparison SSI - C156.272 SSI+ - C156.304...
  • Page 3 The Sensor 1 and Sensor 2 ports are used to connect to the Draper Interior Sun Sensor (C156.282) directly. Please note: Other Draper sensors or 3rd party sensors can be connected to Sensor Ports 1 & 2 using the SSI RJ45 port adapter (C103.154).
  • Page 4: Section 3 - Main Screen

    INSTRUCTION PROGRAMMING Section 3 - Main Screen The main screen shows the current date and time, as well as the current readings for each configured sensor. You can press the to access the Configuration Menu. May 8 10:16PM Not Set Name VV.V UNIT (Units depend on the sensor type) Name VV.V UNIT Name VV.V UNIT...
  • Page 5 INSTRUCTION PROGRAMMING Section 4.2 - Sensor Groups The sensor group configuration menu allows for the programming of up to eight sensor groups. Each group can be configured to use any number of the same type of sensor to control a group of shades. See sections 4.5-4.8 for a description of the control options for each sensor type.
  • Page 6 INSTRUCTION PROGRAMMING Section 4.3 - Schedules The schedule configuration menu allows for the programming of up to eight scheduled events. Each scheduled action can override a group of shades at a specified time, or a time relative to sunrise or sunset. Three priority levels allow schedules to work correctly with other control elements in the system.
  • Page 7 INSTRUCTION PROGRAMMING Section 4.4 - Glare Groups (SSI+ ONLY) Configuration Glare Groups Group 1 Settings (SSI+ ONLY) Sensors Time >Azimuth >Time XXX˚ (0 ˚) >Group 1 156˚ Sensor Groups (Show Azimuth if set >Apr 09, 2018 10:23PM Elevation XX˚ (0 ˚) Location Group 2 Schedules...
  • Page 8 INSTRUCTION PROGRAMMING Section 4.5 - Sun Sensor Parameters - Priority 10 / Pyranometer Parameters - Priority 10 If the level goes below Cloud for the Up Delay time, Group 1 Params then open the shades. >Auto Control If it goes above the Cloud level for the Dn Delay time, then fully close the shades.
  • Page 9 INSTRUCTION PROGRAMMING Tries to keep the sensor level in a certain range. Group 1 Params If the level goes below the low level for more than the delay time, >Range Control then open the shade when the average of Low and High level is reached. Low XXX.X kLux If the level goes above the high level for more than the delay time, Delay XXXX s...
  • Page 10 INSTRUCTION PROGRAMMING Section 4.6 - Rain Sensor Parameters - Priority 5 If it detects rain for the Rain Dly time then open the shades. Group 1 Params >Override Open If it doesn’t detect rain for the Clear Dly time then clear the override. Rain Dly XXX s Clear Dly XXX s If it detects rain for the Rain Dly time then close the shades.
  • Page 11 INSTRUCTION PROGRAMMING Section 4.8 - Temperature Sensor Parameters - Priority 10 If the temperature goes above the threshold for the hot delay time, Group 1 Params then open the shades. >Override Open If it goes below the threshold for the cold delay time then clear the override at that priority.
  • Page 12 INSTRUCTION PROGRAMMING SSI Sensor / Scheduler Interface - Part# C156.273 SSI+ Sensor / Scheduler Interface with Glare Control - Part# C156.304...