Additional Maintenance: Condenser
To Clean the Air Cooled Condenser
1. Remove the front panel.
2. Push and release the Off button.
3. Remove the top panel.
4. Remove the left and right side panels.
5. Replace the air filters.
6. Check the fan blade and condenser for grease
or dust build up.
Because air flow is from the inside of the cabinet
out, the inside of the condenser fins will have the
most build up.
A. Place the inlet hose of a vacuum cleaner in
the condenser shroud.
B. While the vacuum cleaner is on, blow
compressed air from the back of the condenser
thru the fins.
C. If grease is present, use coil cleaner on the
condenser. Be sure to wipe up any excess coil
cleaner.
7. Additional access can be gained by removing
the top of the fan shroud.
(see page 34)
8. After cleaning, return all panels except the right
front to their original positions.
9. Push and release the Freeze button.
10. Replace the front panel.
Right Side
View of Unit
with Top of
Shroud
Removed.
¼ Turn
Fastener
Removable
Part of
Shroud
¼ Turn
Fastener
May 2000