Additional Maintenance

To drain reservoir completely (if desired):
1. Remove front panel.
2. Push and hold the Off button.
3. Push and hold the Clean button for 3 seconds
to activate the purge valve.
To Sanitize the Ice Storage Bin
1. Remove all ice.
2. Remove baffle.
3. Switch ice machine OFF or wait for it to be in a
cleaning cycle.
4. Mix a 1 gallon solution of warm (95-115
water and sanitizer. Follow local codes for
sanitizer.
5. Wash or spray the entire interior of the ice
storage bin with the sanitizer solution. This
includes the bottom of the ice machine and the
inside of the door, the door gaskets (if any) and
door frame.
6. Pour excess sanitizer into the bin to flush the
drain system.
7. If the approved sanitizer requires a rinse, rinse
all interior surfaces with potable water.
Additional Maintenance: Water Distributors
It may become necessary to remove the water
distributors from the top of the evaporator and
clean (de-mineralize) them outside of the ice
machine.
1. Remove front panel.
2. Push and release the OFF button.
3. Remove the evaporator cover.
4. Lift up at the center of the water distributors and
disconnect the distributors from the manifold.
5. Repeat for all evaporators and distributors.
6. Examine the top of the evaporators. The Water
Distribution Channels must be free from mineral
build up. If build up is evident, scrub the channels
with Scotsman Ice Machine Cleaner and a plastic
bristle brush.
o
F.)
7. Examine the water distributors. Although they
are made of a material that is resistant to mineral
build up, some may be present. Soak or scrub the
distributors in or with a solution of Scotsman Ice
Machine Cleaner and warm potable water.
8. Return the water distributors to their normal
installed position.
Distributors Must be Fully Seated as Shown
9. Return all panels to their original positions.
10. Push and release the clean button to flush the
water system.
11. After the machine stops, push and release the
Freeze button.
12. Replace the front panel.
May 2000