Additional Maintenance: Ice Sensors And Water Level Sensor - Scotsman CME1056 User Manual

Cme1056 series;
Hide thumbs Also See for CME1056:
Table of Contents

Advertisement

CME1056

Additional Maintenance: Ice Sensors and Water Level Sensor

The ice sensors use a system of infrared emitting
and receiving components to sense ice. They are
located at the bottom of the ice outlet port. They
must be free of mineral build up to function
properly. To check:
1. Remove front panel.
2. Push and release the off button.
Cube
Deflector
3. Remove the evaporator cover.
4. Remove the cube deflector.
5. Remove the cascading shield.
6. Pull the right sensor out of its socket.
7. Pull the left sensor out of its socket.
8. Examine the bottom of the brackets, there are
two sensors in each bracket, check that they are
clear of mineral build up. They may be wiped clean
with ice machine cleaner to assist in removal of
the build up. Be sure to drain the reservoir or go
thru a Clean cycle to remove residual cleaner.
Note: Do NOT use abrasive materials or cleaner
on the bin sensor lenses. A soft toothbrush is an
effective tool for cleaning these sensors.
9. Reverse to reassemble.
Lens
Cascading
Shield
Ice Sensor
Water Level Sensor:
Clean the lenses inside the water level sensor.
1. Remove the sensor from its installed position.
2. Remove dust cover.
3. Wipe lenses clean with a cotton swab.
Dust Cover
Reverse to Reassemble.
May 2000
Page 26
Lenses

Advertisement

Table of Contents