INSTALLATION
The sensors must be paired in this order Roof, Bedroom, Lounge then Outside.
Sensor - Pairing
- Before starting the pairing process, ensure the touch screen is connected to
the Ceiling Controller Box.
- Power on the Ceiling Controller Box and press and hold the button within 10 seconds.
- The controller will give a long beep and the sensors will be ready to pair.
- First pair the roof sensor by removing the battery and clear plastic battery insulator
then reinsert the battery.
- After 3 seconds the LED on the front of the sensor will flash 3 times
and the controller will beep.
- Replace the battery cover and mount the roof sensor with the adhesive back
- Turn on the touch screen to verify the roof sensors has been paired.
- The bedroom temperature reading will show 99°C to indicate the next sensor to be paired
is the bedroom sensor.
- Go to the bedroom, put in the battery and hold the sensor up to the desired location
and look for 3 flashes.
- If there are less than 3 flashes see the trouble shooting guide.
- Check the touch screen to see if the sensor paired successfully and which sensor
to pair next.
- Remember, the pairing order is Roof, Bedroom, Lounge then Outside.