SmartVent POSITIVE Series Installation Manual

SmartVent POSITIVE Series Installation Manual

Advertisement

Quick Links

POSITIVE PRESSURE SELECTION GUIDE

Would you like the Evolve
What is the size of
temperature and humidity sensor
your home (m2)?
capabilities and Tablet?
Up to 70m²
-
Yes
Up to 100m²
No
Yes
Up to 280m²
No
Yes
Up to 560m²
No
IMPORTANT
If you exceed the number of rooms listed in the selection guide above, the performance of the system
For the SV06 systems, a total of 6 extension kits can be added, however do not exceed 3 extension kits per branch of the system.
Kit
SV01
SV01C
Second Air Source Kit
-
DCT2134
Outdoor Air Supply Kit
FAN6264
FAN6264
Heat Transfer Kit
-
-
1 kW
DCT2123
DCT1226
Tempering
2 x 1 kW
-
-
Heater
2 kW
-
-
1.6 kW
DCT4039** DCT4039**
Digital PTC
Room Heater
2.4 kW
DCT4040** DCT4040**
1.6 kW
-
-
Evolve PTC
Room Heater
2.4 kW
-
-
Additional Fan Kit – 150mm
-
FAN5836
Additional Fan Kit – 200mm
-
FAN5837
* DCT1491 / DCT3418 consist of 2 x 1kW units for installation into each branch of an SV06/E system.
** When adding more than one PTC Room Heater into the digital system contact Simx Technical Support
for advice on 09 259 1660 BEFORE PLACING ORDER.

Additional Information

These recommendations are based on the standard components in the system.
This selection guide assumes 2.4m stud height, if greater please increase the square metre size by 4% for every 0.1m of additional stud
height. For example for a 2.8m stud height, increase your house size by 16%.
This selection guide assumes that there is sufficient ceiling space to install all componentry. If you choose to exceed the number of rooms listed
in the selection guide above, the performance of the system can not be guaranteed.For the SV06 systems, a total of 4 extension kits can be
added. However, please do not exceed 2 extension kits per branch of the system.
General enquiries ph: 0800 140 150
Technical support ph: 09 259 1662
0800 140 150
Distributed by: Simx Limited
Simx reserves the right to alter technical
specifications without prior warning.
PUB1299 Iss03 06/16
How many rooms do you
SmartVent System
wish to distribute to?
1
SV01C
2 - 3
Extension Kit
1
SV01 (no controller)
2
SV02E
3
Extension Kit
2
SV02
3
Extension Kit
4
SV04E
5 - 6
Extension Kit/s
4
SV04
5 - 6
Extension Kit/s
6
SV06E
7 - 12
Extension Kit/s
6
SV06
7 - 12
Extension Kit/s
SV02
SV02E
SV04
SV04E
SV06
DCT2134
DCT2128
FAN6264
-
FAN2028 (1 branch)
FAN2027
FAN2028
FAN4438 (both branches)
DCT1226
DCT3478
DCT1483
DCT3231
DCT1483
-
-
-
-
DCT1491*
-
-
DCT1484
DCT3230
DCT1484
DCT4039**
-
DCT4039**
-
DCT4039**
DCT4040**
-
DCT4040**
-
DCT4040**
-
DCT4037
-
DCT4037
-
DCT4038
-
DCT4038
FAN5836
FAN5836
FAN5837
FAN5837
Installation Guide
Order Codes
SmartVent POSITIVE
FAN2023
This installation guide is intended for the installation of the following SmartVent models:
DCT2276
SV01
SV01C
FAN1056
FAN2113
Setup guides for the controller are supplied separately dependent on controller type.
DCT2276
FAN0939

Definitions

DCT2276
FAN2115
Before use please read and understand these definitions.
DCT2276
FAN1057
DCT2276
CAUTION CAUTION indicates the possibility of damage to the equipment, installation or premises if
FAN2117
DCT2276
NOTE:
FAN1064
-
The appliance is not to be used by persons (including children) with reduced physical, sensory or mental capabilities,
DCT2276
or lack of experience and knowledge, unless they have been given supervision or instruction
-
Children should be supervised so that they do not to play with the appliance.
-
Ensure that the fan is switched off from the supply mains before removing the guard.
-
The fan is to be installed so that the blades are more than 2,1 m above the floor
SV06E
-
Precautions must be taken to avoid the back-flow of gases into the room from the open flue of gas or other
DCT2135
fuel-burning appliances.
-
-
-
Isolator switch must be incorporated in the fixed wiring in accordance with AS/NZS wiring rules.
CAUTION: In order to avoid a hazard due to inadvertent resetting of the thermal cut-out, this appliance must not be
supplied through an external switching device, such as a timer, or connected to a circuit that is regularly switched on
DCT3231
and off by the utility
DCT3418*
DCT3230

Warnings

-
Read all instructions carefully before commencing installation.
-
Switch off mains supply before making any electrical connections.
-
DCT4037
All wiring should be performed by a registered electrical contractor and comply with local
-
DCT4038
wiring regulations. This appliance is not intended for use by young children or infirm persons
-
FAN5836
without supervision.
-
FAN5837

Pre-install check

Identify rooms

Identify the room/s that require the most ventilation. If installing a Heat Transfer upgrade, identify your heat source room.

Ceiling integrity

Ceiling penetrations/openings (i.e. access hatch, open backed down lights) between the living spaces and roof space
reduce the effectiveness of the system. Where possible these should be sealed.

Roof space integrity

The roof space MUST be inspected to ensure it does not have any conditions that may cause the system to draw
moisture into the home. Conditions may include: Roof leaks / Tile roofs requiring
re-coating / Open wall cavities / Gutter leaks or other building envelope leaks.

Fan location

Scan QR code
The fan is designed to be suspended from the rafters to avoid vibration or resonance. Hanging straps are provided. Avoid
for more details
installation near or over bedrooms.
on SmartVent
systems.

Existing extraction

Bathroom, kitchen and dryer extract fans must be exhausted to the outside of your house and not into the roof cavity.
SV02
SV04
SV06
WARNING and or the use of the symbol refers to conditions where the possibility of injury
or death exists if the procedure is not followed.
a procedure is not followed.
NOTE: provides additional information intended to clarify points, procedures or instructions.
SV02E
SV04E
SV06E

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the POSITIVE Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for SmartVent POSITIVE Series

  • Page 1 Order Codes your home (m2)? wish to distribute to? capabilities and Tablet? SmartVent POSITIVE SV01C FAN2023 This installation guide is intended for the installation of the following SmartVent models: Up to 70m² 2 - 3 Extension Kit DCT2276 SV01 SV01C...
  • Page 2 Power and Control (Evolve only) Ducting Heat SV02 Summer Auxiliary Transfer OPTION 1 Damper Main Fan Damper Heater SmartVent Router Configuration SSID: evolve >1m >1m PASSWORD: smartvent IP ADDRESS: 192.168.1.171 INSULATED ACOUSTIC DHCP RANGE: 192.168.1.172 - 180 DANGER!! HIGH VOLTAGE >300mm...

This manual is also suitable for:

Sv01Sv01cSv02Sv04Sv06Sv02e ... Show all

Table of Contents