  • Page 1 Breeze Electric Breast Pump Instructions & Assembly Model: PA209DM...
  • Page 3: Congratulations

    Congratulations on your new Rumble Tuff ® Breeze Pro Electric Breast Pump (Multi-user)! The Rumble Tuff ® Electric Breast Pump Duo is perfect for many occasions. ● Collecting breast milk while you're away from your baby ○ for example: when you're at work ●...
  • Page 4: Table Of Contents

    About Your Rumble Tuff Breeze Pro ..........18 ............18 Electric Breast Pump Main Unit ..............18 Expression Indicator Lights ........19 How to Use Your Rumble Tuff Breeze Pro ...................21 Suction Level ............22 M Button (My Favorite Pattern) ..............23 How to Adjust the Clock ..............
  • Page 5 ........28 ....... 28 How to Assemble the Manual-Pump Diaphragm Kit ....29 How to Assemble the Expression Collection Combo Kit Using your Rumble Tuff Sweet Essence ........30 ........... 30 Expression Collection Combo Kit Storage and Preparation of Breast Milk ........
  • Page 6: Important Safeguards

    Rumble Tuff Customer Service immediately. • Use only the AC/DC Adapter that comes with the Breeze Pro Breast Pump • Never leave plugged-in product unattended. • Plug the AC/DC Adapter into the electrical outlet, before connecting the Power Cord into your pump.
  • Page 7: Caution

    • Do not overboil product materials; to prevent premature aging. • Do not use any accessories, parts, or attachments that are not recommended by Rumble Tuff. Doing so may affect the performance of your breast pump and void the warranty.
  • Page 8: Accessories And Parts

    Assemble Instruction Cleaning Instruction Warning: Rumble Tuff Breeze Pro Electric Breast Pump is designed to be used with Rumble Tuff Expression Collection Combo Kits only. The Anti- Backflow Diaphragm on top of the Collection Kit prevents the breast milk over flow through the Tubing into the Pump Main Unit. This special feature makes the Pump suitable for multiple-users.
  • Page 9: Expression Collection Combo Kit

    Accessories and Parts Expression Collection Combo Kit (Sold Separately) Diaphragm Cup with O-Ring Silicone Cushion Breast Shield Body Membrane Valve Bottle Adapter Collection Bottle Bottle Base...
  • Page 10: Bottle Assembly

    Bottle Assembly How to Assemble the Expression Collection Combo Kit Hold the Breast Shield Body in one hand and make sure the bottle-thread side opening is facing up. Insert the Membrane Valve into the bottom of the Breast Shield Body. Verify that the membrane of the Membrane Valve is flat.
  • Page 11 Bottle Assembly How to Assemble the Expression Collection Combo Kit (Continued) If desired, place the Silicone Cushion into the Flange of the Breast Shield. Note: Your Electric Breast Pump will work with or without the Silicone Cushion. Your comfort depends on your preference. Push the center of the Silicone Cushion into the Flange.
  • Page 12 Bottle Assembly How to Assemble the Expression Collection Combo Kit (Continued) Ensure that the Diaphragm is securely mounted in place. This is crucial in order to achieve proper suction and prevent milk back flow. Place the Cap on the Cup and Diaphragm.
  • Page 13 Bottle Assembly How to Assemble the Expression Collection Combo Kit (Continued) Twist clockwise until it locks into place. Twist the Bottle Adapter onto the Breast Shield Body. Twist on the Collection Bottle for a secure fit. Set the Collection Bottle in the Bottle Base.
  • Page 14 Bottle Assembly How to Assemble the Expression Collection Combo Kit (Continued) The Expression Collection Combo Kit is assembled. Make sure the Tubing Adapter is properly inserted into the Tubing Adapter Inlet on the Electric Pump Main Unit. To Convert Your Double Pump Into a Single Pump: Remove one tube and close the cap.
  • Page 15: Cleaning Instructions

    Cleaning Instructions Sanitize Prior to First Use: Before you use your Rumble Tuff Breeze Pro Electric Breast Pump for the first ® time, disassemble and boil all parts of the Expression Collection Combo Kit in water for 10 minutes. • Be sure to use enough water to keep all parts afloat while boiling.
  • Page 16: After Every Use

    Do not use a dish towel to rub or pat items dry because doing so may transfer germs to the items. Rumble Tuff also provides a Drying Mess Bag for your convenience to air dry all Collection...
  • Page 17 If you see breast milk inside the tubing or tubing connector do not attempt to wash, clean or sterilize the tubing or tubing connect. Instead contact Rumble Tuff Customer Service. • E-mail: customerservice@rumbletuff.com • Toll-Free: (855) 228-8388...
  • Page 18: For Extra Protection, Sanitize

    Cleaning Instructions For Extra Protection, Sanitize For extra germ removal, sanitize Collection Kit parts at least once daily. Sanitizing is especially important if your baby is less than 3 months old, was born prematurely, or has a weakened immune system due to illness or medical treatment (such as chemotherapy for cancer).
  • Page 19: Store Safely Until Needed

    Tubing Cleaning Instructions: • Rumble Tuff breast pump tubing are designed to not touch the pumped milk and does not need to be cleaned routinely. • Keep a spare set of tubing on hand in case the set you are using gets soiled or damaged.
  • Page 20: About Your Rumble Tuff Breeze Pro

    About Your Rumble Tuff Breeze Pro Electric Breast Pump Main Unit Expression Button / Vacuum Adjusting Knob Tubing Adapter Inlet LCD Screen M Button Power Button Dust-Proof Cover AC/DC Adapter Inlet Expression Indicator Lights Swift Expression Indicator Natural Expression Power Indicator...
  • Page 21: How To Use Your Rumble Tuff Breeze Pro

    About Your Rumble Tuff Breeze Pro How to Use Your Rumble Tuff Breeze Pro Check for correct fitting of the Shield. Hold the Expression Collection Combo Kit to your breast so that your nipple is centered in the Flange. 24~25mm Open the dust-proof cover and plug in  ...
  • Page 22 About Your Rumble Tuff Breeze Pro How to Use Your Rumble Tuff Breeze Pro (Continued) Adjust the suction in the Swift Expression to your comfort level during pumping by rotating the Vacuum Adjusting Knob clockwise (up/+) or counter wise (down/-)
  • Page 23: Suction Level

    Breast Shield and the breast,   similar to the way you break away from your baby's suction. If the Rumble Tuff ® Electric Breast Pump Duo is left on, but unattended for more than 30 minutes, the Pump will automatically shut-off.
  • Page 24: M Button (My Favorite Pattern)

      clockwise (up/+) or counterclockwise (down/-) M Button (My Favorite Pattern) One of the great features of your Rumble Tuff Breeze Pro is the M Button (My Favorite Pattern). You can easily set and recall your personal expression pattern by pressing the M Button. It is extremely helpful if you usually use Natural Expression setting to express your milk.
  • Page 25: How To Adjust The Clock

    About Your Rumble Tuff Breeze Pro How to Adjust the Clock 1. While in the Clock/Standby Mode, press and hold the M Button for 3 seconds to go into Clock Setting mode. A beep will sound and the AM/PM icon will flash.
  • Page 26: How To Adjust The Alarm

    About Your Rumble Tuff Breeze Pro How to Adjust the Alarm The Alarm Clock Mode is designed to remind you when it's time for your next pumping cycle. By keeping a regular expression pattern, your body maintains a good milk supply. After you set the time interval between each pumping session, the alarm countdown will automatically start after the previous pumping cycle has ended.
  • Page 27: How To Mute Chimes

    About Your Rumble Tuff Breeze Pro How to Adjust the Alarm (Continued) Alternatively shows Press Press The Power Off time of last operation the Expression the M Button Button ** Turn to adjust Time between pumping Alarm On sessions Press...
  • Page 28: Power Options

    Electrical safety can only be achieved when using the AC/DC Adapter provided with the Pump. Use of any another Adapter poses a safety risk and/or the warranty may be voided. Built-in Li-Ion Rechargeable Battery Your Rumble Tuff Breeze Pro contains a built-in Li-Ion rechargeable battery. • Fully charge the battery for 12 hours before the first use on battery power.
  • Page 29: Built-In Li-Ion Rechargeable Battery

    Power Options Built-in Li-Ion Rechargeable Battery (Continued) • Your pump may not run immediately on battery power if it has been stored in a heated location. If this is the case, you can allow the battery to cool down while still using it on an external power source. Note : The Li-Ion Rechargeable Battery used in this device may present a risk of fire or chemical burn if mistreated.
  • Page 30: Rumble Tuff Sweet Essence Assembly

    Rumble Tuff Sweet Essence Assembly How to Assemble the Manual-Pump Diaphragm Kit Adjusting Valve Handle Adjusting Valve Stem Valve Stem Manual Manual Diaphragm Diaphragm Handle Cup with O-Ring For the installation of the Membrane Valve and Silicone Cushion, please refer to Bottle Assembly on P.
  • Page 31: How To Assemble The Expression Collection Combo Kit

    Rumble Tuff Sweet Essence Assembly How to Assemble the Expression Collection Combo Kit "U" shape slot Place the "U" shape slot of the Handle onto the recess of the Adjusting Valve Stem. Swift Expression Natural Expression There are 2 recesses on the Adjusting Valve Stem.
  • Page 32: Using Your Rumble Tuff Sweet Essence

    Using your Rumble Tuff Sweet Essence Expression Collection Combo Kit Note: There are two recesses for attaching the handle to the Manual Pump. You can toggle between these two settings by pushing the Adjusting Valve Stem away from the “U” shape tip of the Handle to dislocate the connection. Reattach the tip of the Handle using a different recess on the Adjusting Valve Stem.
  • Page 33 Using your Rumble Tuff Sweet Essence Expression Collection Combo Kit Hold the Manual Breast Pump to your breast so that your nipple is centered inside the Breast Shield, then squeeze the handle toward the bottle to test the suction. Note: If an adjustment is necessary, turn the round knob of the Adjusting Valve to a comfortable suction level.
  • Page 34: Storage And Preparation Of Breast Milk

    Storage and Preparation of Breast Milk...
  • Page 35 Storage and Preparation of Breast Milk(cont.)
  • Page 36: Troubleshooting

    Troubleshooting Interruption of Electrical Service If you experience a power interruption due to a power surge or other factors, while operating your pump using the AD/DC Adapter, try the following: • Unplug the AC/DC Adapter from the electrical outlet and wait at least for 5 seconds or until the power has resumed.
  • Page 37: No Response While Operating Adjusting Knob And Mode Button

    If damaged, replace the Membrane Valve with one of the spare valves provided with your Rumble Tuff Breeze Pro. No response while operating Adjusting Knob and Mode button You CANNOT adjust the suction level or switch between Swift Expression and Natural Expression while in My Favorite Pattern.
  • Page 38: Condensation Or Milk In Tubing

    Condensation or Milk in Tubing: If you find condensation in the air tube, wash and dry it immediately or replace the tubing. Rumble Tuff Breeze Pro Electric Breast Pump has anti-backflow diaphragm on top of the Collection Kit to prevent milk over flow through the tubing into main breast pump unit.
  • Page 39: Emc/Technical Description

    EMC/Technical Description The breast pump needs special precautions regarding EMC and needs to be installed and put into service according to the EMC information provided in the instructions for use. Portable and mobile RF communications can affect the breast pump. Note This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
  • Page 40 EMC/Technical Description(Continued) Guidance and manufacturer’s declaration – electromagnetic emissions This breast pump is intended for use in the electromagnetic environment specified below. The customer or the user of the breast pump should assure that it is used in such an environment . Electromagnetic Emission tests Compliance...
  • Page 41 This breast pump is intended for use in the electromagnetic environment specified below. The customer or the user of the breast pump should assure that it is used in such an environment. The Breeze Pro Breast Pump has anti-backflow as essential performance, which is not influenced by electro - magnetic.
  • Page 42 EMC/Technical Description(Continued) Electrical fast ± 2 kV, 100 kHz ± 2 kV, 100 kHz Mains power quality transient/burst repetition repetition should be that of a IEC 61000-4-4 frequency frequency typical commercial or hospital environ- ment. Mains power quality Surge ± 0.5 kV, ± 1 kV ±...
  • Page 43 EMC/Technical Description(Continued) Guidance and manufacturer’s declaration – electromagnetic immunity This breast pump is intended for use in the electromagnetic environment specified below. The customer or the user of the breast pump should assure that it is used in such an environment . IEC 60601 Compliance Electromagnetic...
  • Page 44 EMC/Technical Description(Continued) WARNING: Portable RF communications equipment (including peripher - als such as antenna cables and external antennas) should be used no closer than 30 cm (12 inches) to any part of the breast pump including cables specified by the manufacturer. Otherwise, degradation of the performance of this equipment could result.
  • Page 45: Warranty

    This warranty gives you specific legal rights and you may also have other rights, which vary by location. In the event that this product is found by Rumble Tuff to not meet the above limited warranty standard, as the purchaser's sole and exclusive remedy, Rumble Tuff will repair, or, at the discretion of Rumble Tuff, replace this product without charge for such replacement parts or labor.
  • Page 46: Technical Data

    Technical Data Power Requirements: • AC/DC Adapter (included) North American Plug Configuration: 100V~240V AC, 50/60 Hz, 0.4A, wall • Plug type AC/DC Adapter with DC 9V/1.3A output. • Battery Non-replaceable li-Ion battery; 7.4V 2200mAh Technical Specifications: • Vacuum: Swift Expression -75~-179mmHg (-10~-24kpa) Natural Expression -75~-250mmHg (-10~-33.3kpa) • Ambient Temperature range: +10°C to 40°C (50°F to 104°F)
  • Page 47: Symbols Legend

    Symbols Legend...
  • Page 48 Symbols Legend(Continued)
  • Page 49 865 N 1430 W Orem UT 84057-6402 Tel: (801) 609-8168 Fax: (801) 796-2688 www.rumbletuff.com 75-PA209DM-RT00 Ver : 200410...