3.3.3 Tone Open Numbers

These steps will program the tone open numbers for Relays 0, 1 and 2. You will need to enter a four-digit number (see chart
below) to set the relay functions. If a function is not desired, enter # in place of a number. If Expansion boards are connected
to the system, there is no need to set a momentary open tone open number for the Expansion control relay(s). However, you
may want to set HOLD and DEACTIVATE tone numbers, which will allow management to have a function to automatically unlock
all doors/gates controlled by a Expansion board (refer to 5.3.2).
Factory setting is: Relay 0 = ####, Relay 1 = 9876, Relay 2 = 5432.
JKL
JKL
OPER
OPER
1. Press
and enter your four-digit MASTER CODE
0 0
5 5
OPER
OPER
2. Press
(beep) to set Relay 0, OR
0 0
3. Enter the four-digit tone open number code, then press
(Example: If you want a relay to have a momentary activation function only, and you want that relay to momentary activate
when the number 9 is pressed, enter 9 # # #. If a function is not desired, enter # in place of a number. Do not duplicate tone
open numbers, Example: don't set relay 0, 1, and 2 tone-open numbers all to 9.)
4-Digit Tone Open Number Code
1st Digit
2nd Digit
3rd Digit
4th Digit
4. Repeat steps 2 and 3 to set other relay tone open numbers.
OPER
OPER
5. Press
together to end this programming sequence (beeeeeep).
0 0
Note: Residents will only be able to activate the Momentary activation when using the entry system.
3.3.4 Switch Input Relay
This programming sequence sets which relay(s) will activate when the switch input (main terminals #4 and #6) is activated on
the telephone entry system. The system can be programmed so that only one relay will activate, or any combination of relays
will activate. TIP: The relay that you designate as the primary relay should be programmed to activate from the postal switch
input.
Factory setting = 010 (only relay 1 activates)
OPER
OPER
TUV
TUV
1. Press
and enter your four-digit MASTER CODE
5 5
0 0
2. Enter the three-digit (1's or 0's only) postal relay code, then press
Three-digit positions: 1st digit position - Relay 0, 2nd digit position - Relay 1, 3rd digit position - Relay 2.
To activate a relay - enter a 1 in a digit position.
To NOT activate a relay - enter a 0 in a digit position.
Example: entering 010 will cause only relay 1 to activate. Entering 101 will cause both relay 0 and relay 2 to activate.
OPER
OPER
3. Press
together to end this programming sequence (beeeeeep).
0 0
36
SP
SP
(beep) to set Relay 1, OR
1 1
Momentary activation. Relay will activate for the programmed strike time (3.3.1).
Relay hold. Relay will activate and remain activated until commanded to release.
Relay release. Deactivates the relay hold command.
Relay hold 1-hour. Relay will activate for 1-hour and then will automatically deactivate itself.
s
Activation
(
)
? ?
? ?
? ?
? ?
(beep).
ABC
ABC
2 2
(beep).
Function
? ?
? ?
? ?
? ?
(beep).
(beep).
(beep) to set Relay 2 tone numbers.