PLENA matrix
Problem
The call station is activated
but, announcement did not
come through the system.
Rack units are not found in
target search.
9.1
Customer service
If a fault cannot be resolved, please contact your supplier or system integrator, or go directly
to your Bosch representative.
Bosch Security Systems B.V.
Possible cause
–
Unit has just been turned
on.
–
A chime has been
programmed to play
before any
announcement.
–
The announcement level
is not at a sufficient level
for the selected zone.
–
The user is not speaking
loudly enough towards
the microphone.
–
Ethernet cables have
been disconnected.
–
Unit(s) and/or router are
not on.
–
PC is not connected to
network.
User manual
Troubleshooting | en
Possible solution
–
Check if a cable has
been damaged in the
daisy‑chain.
–
Wait 15 seconds, until
unit has been identified
by the DSP matrix mixer
before attempting to use
it.
–
Wait for LEDs to turn
green on the call station
before talking or
deactivate the chime via
the GUI.
–
Within the GUI check
that all call station levels
are set to appropriately
and the mute is not
activated.
–
Speak slowly and clearly
towards the microphone.
–
Check all unit are
connected to power,
check cabling is correctly
connected, check that
the PC is connected to
the network.
2020-12 | V1.1 |
43