A-8
Using Dual Schedule with Fast-Mate guns on -10
Series Feeders
Configuration 1
K489-9
Dual Schedule Fast-Mate adapter
K575-*
Magnum 400 DS/FM gun
(or competitive DS/FM gun)
Configuration 2
K489-9
Dual Schedule Fast-Mate adapter
K683-1
Dual Procedure Switch (3 pin)
K686-2
"Y" adapter (3 pin +5 pin to 5 pin)
*
Non-DS Fast-Mate gun (Magnum 450WC, Magnum 200, Magnum
300, Magnum 400 and others
K590-6
Water Connection Kit (For DH Drive Only)
Install per the instructions shipped with the kit. One used per
.
gun
K659-1 Gas Guard Regulator (One used per gun)
Adjustable flow regulator with removable adjustor key
for CO
and Argon blend gases. Mounts onto feeder
2
inlet, and reduces gas waste and arc start "blow" by
reducing surge caused by excess pressure in supply
hose.
Install the 5/8-18 male outlet of the regulator to one, or
both of the 5/8-18 female gas inlets on the back panel
of the wire drive. Secure fitting with flow adjuster key
at top. Attach gas supply to 5/8-18 female inlet of reg-
ulator per GMAW Shielding Gas (Installation
Section).
K1449-5 Dual Procedure Remote Control
Provides remote rotating knob encoder control of Wire
Feed Speed and Voltage, along with a dual procedure
selector switch, when the remote control is connected
and REMOTE is selected by the DH-10 Procedure
key. The DH-10 A or B procedure light will also be on
to indicate which procedure is selected by the remote
control.
The 4-pin plug of the remote control connects to the
mating receptacle on the bottom of the DH-10 Control
box. Only one remote is used with a DH-10 control.
The K1450-"L" Extension cable is used to extend the
16 ft (5m) cable attached to the remote control.
Lengths "L" are available to match the Length of the
control to boom mount wire drive cable being used.
.
INSTALLATION
K1558-1 Remote Switch Interface Module, can be
used with the DH-10, using a G3041-2 (or higher)
Control Board.
The module provides for user interface connection of
an external switch (flow switch, etc) which must be
closed to enable the feeder welding operation. Also,
the module provides for interface connection of exter-
nal equipment (fume extractor, etc.) To the moduleʼs
isolated relay contacts which actuate when the feeder
welding gas solenoid is activated (representing weld-
ing operation in process)
When used with the DH-10, the module provides
these input and output switch function connections
independently for each head operation.
This module is necessary when using the K1536-1
waterflow sense kit with the DH-10.