Bosch APC-AMC2-4R4CF Installation Manual page 46

Access modular controller 2
Hide thumbs Also See for APC-AMC2-4R4CF:
Table of Contents

Advertisement

46
en | Appendices
Tab. 7.6: Power supply
Tab. 7.7: RS-485 reader interface
Tab. 7.8: Analog input
Tab. 7.9: Relay output
2020-01 | V02 |
1
Power supply, DC positive (10V - 30V)
2
Shield
3
Power supply (0V)
4
UPS (power good signal) - AC
5
UPS (power good signal) - Battery
6
UPS (power good signal) - DC
7
UPS (power good signal) - Common
1
Reader Supply (10V - 30V)
2
Reader Supply (0V)
3
Shield
4
Data RxTx+
5
Data RxTx-
6
Data shield (PAG)
7
not connected
8
not connected
9
not connected
10
not connected
1
Analog Input, in
2
Analog Input, out
1
Relay Output, normally open
2
Relay Output, common
3
Relay Output, normally closed
1
Power supply for external devices (10V -
30V)
2
Power supply for external devices (0V)
3
Shield
4
Data RxTx+
5
Data RxTx-
Installation manual