• Red frame: Set the UWB channel for interface 4 (IF4) to channel 5 and then click the "Set"
button.
• Green frame: For the "IF2_DW_PRF" parameter, enter the value "DW_enePRF_16Mhz" and
then click the "Set" button.
• Green frame: For the "IF2_DW_PreamblCode" parameter, enter the value
"DW_enePreamblCode_3" and then click the "Set" button.
• Green frame: For the "IF4_DW_PRF" parameter, enter the value "DW_enePRF_64Mhz" and
then click the "Set" button.
• Green frame: For the "IF4_DW_PreamblCode" parameter, enter the value
"DW_enePreamblCode_10" and then click the "Set" button.
• Blue frame: Click the "Reset" button and ensure that the "State" has the "Configured" value. All
configurations have thereby been adopted.
SIMATIC RTLS5201T
Operating Instructions, 08/2023, C79000-G8976-C687-02
Installation and operation
3.2 Operation
19