Troubleshooting - Fanimation SLINGER LP8147SLBN Manual

Table of Contents

Advertisement

Available languages

Available languages

For your own safety turn off power at fuse box or circuit breaker before trouble shooting your fan.
Trouble
1.FAN WILL
NOT START
2.FAN SOUNDS NOISY
3.FAN WOBBLES
EXCESSIVELY
4.NOT ENOUGH AIR
MOVEMENT

Troubleshooting

Probable Cause
1. Fuse or circuit breaker blown.
2. Loose power line connections to the
fan, or loose switch wire connections
in the switch housing.
3. Dead battery in remote control.
1. Blades not attached to fan.
2. Loose screws in motor housing.
3. Screws securing fan blade holders to
motor flywheel are loose.
4. Wire connectors inside housing
rattling.
5. Motor noise caused by solid state
variable speed control.
6. Screws holding blades to blade
holders are loose.
1. Setscrew in downrod support is loose.
2. Setscrew in downrod/hanger ball
assembly is loose.
3. Screws securing fan blade holders to
blades are loose.
4. Blade holders not seated properly.
5. Hanger bracket and/or ceiling outlet
box is not securely fastened.
6. Fan blades out of balance.
WARNING
1. Check main and branch circuit fuses
or circuit breakers.
2. Check line wire connections to fan
and switch wire connections in the
switch housings.
CAUTION: Make sure main power is
turned off !
3. Replace with new battery.
1. Attach blades to fan before operating.
2. Check to make sure all screws in
motor housing are snug (do not
overtighten).
3. Check to make sure the screws which
attach the fan blade holders to the
motor flywheel are tight.
4. Check to make sure wire connectors
in switch housing are not rattling
against each other or against the
interior wall of the switch housing.
CAUTION: Make sure main power is
turned off !
5. Some fan motors are sensitive to
signals from solid-state variable
speed controls. Solid-state controls
are not recommended, choose an
alternative control method.
6. Tighten screws securely.
1. Tighten both setscrews securely in
downrod support.
2. Tighten the setscrew in the downrod/
hanger ball assembly.
3. Check to be sure screws which attach
the fan blade holders to the blades
are tight.
4. Check to be sure the fan blade
holders seat firmly and uniformly to
the surface of the motor housing.
If holders are seated incorrectly,
loosen the screws and retighten.
5. Tighten the hanger bracket screws to
the outlet box, and secure outlet box.
6. Balance blades using balance kit
provided in hardware bag.
1. If possible, consider using a longer
downrod (not included, you can buy
the longer downrod from
fanimation.com).
17
Suggested Remedy

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

Slinger lp8147slblSlinger 0581598Slinger 0795392

Table of Contents