Нормативные требования Евразийского Экономического Союза
Kazakhstan
ЖШС "Хьюлетт Паккард Энтерпрайз" Ресей Федерациясы, 125171, Мәскеу, Ленинград тас жолы, 16A блок
3, Телефон: +7 499 403 4248 Факс: +7 499 403 4677
ЖШС «Хьюлетт-Паккард (К)», Қазақстан Республикасы, 050040, Алматы к., Бостандык ауданы, Әл-Фараби
даңғ ылы, 77/7, Телефон/факс: +7 (727) 355 35 50
Ukraine
Hereby, Hewlett Packard Enterprise Company declares that the radio equipment type [The Regulatory Model
Number [RMN] for this device can be found in the
compliance with Ukrainian Technical Regulation on Radio Equipment, approved by resolution of the CABINET OF
MINISTERS OF UKRAINE dated May 24, 2017, No. 355. The full text of the UA declaration of conformity is
available at the following internet address:
Х'ЮЛЕТТ ПАКАРД ЕНТЕРПРАЗ, 6280 АМЕРИКА ЦЕНТР Д-Р, САН-ХОСЕ, КАЛІФОРНІЯ 95002, США

Special Conditions for Safe Use

WARNING – DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT
The connections on this equipment are not intended to be connected or disconnected when an explosive
atmosphere is present.
Only qualified Ex person are allowed for on-site installation and electrical connections of equipment.
Manual switch TS4V-2PL-R are protected by minimum IP66 enclosure, it is not allowed to operate the switch
in hazardous area.
Required protection shall be applied to avoid the mechanical damage of high risk occurred by the final
installation.
The equipment must be installed and used in an area of at least pollution degree 2,as defined in IEC 60664-1.
Only ATEX/IECEx cable glands as specified in the instruction to be installed and used on the enclosure,and
IEC/EN 60079-14 shall be observed when installing. Suitable type of protection Cable gland to be selected
with spec: M20x1.5 with minimum IP66 rating.
Type-C USB port is not used in hazardous area.
Damaged Protective Vents have to be replaced immediately.
Earthing system shall be finished in accordance with user manual before use.
Use cable gland, stopping plug, conduit fitting or similar device with ingress of protection of IP66, and the
installation shall meet the requirements of CEC (for Canada) and NEC (for USA) for wiring method in Division
2 and is subjected to acceptance of local authorities having jurisdiction.
Wipe with a wet cloth and use PPE for routine maintenance.

Standard Compliance

EN 60079-0:2018
EN 60079-7:2015/A1:2018
IEC 60079-0:2017 Edition 7.0
IEC 60079-7:2015+A1:2017 Edition 5.1
CSA C22.2 No.213-17
UL 121201 ninth edition
Aruba 570EX Series Hazardous Location Access Points
HPE Russia: ООО "Хьюлетт Паккард Энтерпрайз" Российская Федерация, 125171, г.
Москва, Ленинградское шоссе, 16А, стр.3, Телефон: +7 499 403 4248 Факс: +7 499 403
4677
'HPE Kazakhstan': TOO «Хьюлетт-Паккард (К)», Республика Казахстан, 050040, г.
Алматы, Бостандыкский район, проспект Аль-Фараби, 77/7, Телефон/факс: + 7 727
355 35 50