Repair And Maintenance; Daily Maintenance; Periodic Inspection - TE Connectivity HT11K Operating Instructions Manual

Hand tool nanomqs 0.13-0.35 sq.mm
Table of Contents

Advertisement

HT11K Hand Tool NANOMQS 0.13-0.35 SQ.MM
Then you can remove the crimped terminal from the crimping die. Ensure that the
wire stop is opened. If the terminal is stuck, jiggle it slightly to remove it from the ter-
minal holder.
Check the crimp height of the crimped terminal, Refer to the information in the TE
Connectivity processing specification and drawing.
The hand tool is ready for use again.
7

Repair and maintenance

7.1

Daily Maintenance

The following daily maintenance tasks should be performed by the responsible operator:
Using a soft, clean brush or a lint-free cloth, remove dirt, dust, moisture and other
residue from the hand tool. Do not use any hard or abrasive tools or materials that
could damage the hand tool.
Apply sewing-machine oil to all pivot points and bearing surfaces. Do not lubricate
excessively.
When the hand tool is not needed, store it in a clean and dry location.
7.2

Periodic inspection

The hand tool should be inspected periodically by suitably qualified staff according to
the level of use, and the inspections should be documented.
Check the hand tool for wear and damage, particularly in the crimping nest areas.
OPERATING INSTRUCTIONS
411-18608-1_Rev.A
Figure 4: Crimp terminal (left), check the crimped terminal (right)
Page 8 - 9