Address Description
40564
TCP disconnection timeout value, 5 to 65535, in
second, 0 to disable.
Only for Modbus TCP protocol
40565
Module reset timeout value, 30 to 65535, in
second, 0 to disable.
Only for Modbus TCP protocol
40865
RTC year, 2000 to 2159
40866
RTC month, 1 to 12
40867
RTC date, 1 to 31
40868
RTC hour, 0 to 23
40869
RTC minute, 0 to 59
40870
RTC second, 0 to 59
40871
Total number of log records, low word
40872
Total number of log records, high word
40873
The starting record to read log data, low word
40874
The starting record to read log data, high word
40875
The status of the data logging, 0: stopped, 1:
running
40876
The data logger command, 0: stop, 1: run, 2: run
in period mode
40877
Continue writing when data logger is full, 0: no, 1:
yes
40878

Hour of the data logger sampling period, 0 ~ 24

40879
Minute of the data logger sampling period, 0 ~ 59 R/W
40880
Second of the data logger sampling period, 0 ~ 59 R/W
40881
Starting year when logging in period mode, 2000 ~
2159
40882
Starting month when logging in period mode, 1 ~
12
40883
Starting date when logging in period mode, 1 ~ 31 R/W
40884
Starting hour when logging in period mode, 0 ~ 23 R/W
40885
Starting minute when logging in period mode, 0 ~
59
B-3. DL-110S-E Modbus Address Mappings (Base 1)
Attribute
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R
R
R/W
R/W
R
R/W
R/W
R/W
R/W
R/W
R/W