Advertisement

Quick Links

Models
ADPB12PPT
Read this manual carefully before installing, operating or servicing this equipment. It's the responsi-
bility of the employer to ensure this manual is read by the operator. Please preserve this manual.
This document is issued with Product Serial No
Operation and Maintenance Guide
ADPB12PPT
Descriptions
Polypropylene with PTFE fitments

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ADPB12PPT and is the answer not in the manual?

Questions and answers

Summary of Contents for Teryair ADPB12PPT

  • Page 1 Operation and Maintenance Guide ADPB12PPT Models Descriptions ADPB12PPT Polypropylene with PTFE fitments Read this manual carefully before installing, operating or servicing this equipment. It’s the responsi- bility of the employer to ensure this manual is read by the operator. Please preserve this manual.
  • Page 2: Table Of Contents

    Operating and Safety Instructions Suggested Lubricants Suggested site selection and installation recommendations Troubleshooting Maintenance Diassembly and Re-assembly Bill of Materials for ADPB12PPT Pumps Exploded View for ADPB12PPT Pump Dimensional Data Repair Kits for ADPB12PPT Pumps Repair and Replacement Kits Eu Declaration Of Conformity...
  • Page 3: Pump Nomenclature

    Operation and Maintenance Guide ADPB 12 Plastic Pump Series Page 3 Pump Nomenclature Air Valve Type Pump Size Material of Construction Material of Bolted or Threading on Inlet Diaphragm Clamped and Outlet 06 - 1/4” 12 - 1/2” 15 - 1/2” DP - Classic AL - Aluminium R- NPT...
  • Page 4 Operating Instructions The Teryair diaphragm pump generates a alternate stroking of the diaphragms against the fluid in the liquid chambers of the Pump. This reciprocatory action is responsible for the fluid being pumped.
  • Page 5: Suggested Lubricants

    Operation and Maintenance Guide ADPB 12 Plastic Pump Series Page 5 Caution: Temperature limitations and diaphragm options Excellent choice when pumping highly aggressive fluids such as aromatic or chlorinated hydrocarbons, PTFE acids, caustics, ketones and acetates. Temperature range +4°C to +104°C (+40°F to +220°F) Suggested Lubricants Brand Above 27 Deg C (...
  • Page 6 Operation and Maintenance Guide ADPB 12 Plastic Pump Series Page 6 Location selection Suction Pump location must be easily accessible with reasonable Ensure that the suction head after installation is well space around for maintenance operations. within the pumps suction capabilities Pump dimensional data for each variant is available in section showing exploded views Muffler...
  • Page 7: Troubleshooting

    Operation and Maintenance Guide ADPB 12 Plastic Pump Series Page 7 Troubleshooting Serial No Description Causes Remedial Action Pump stops and Insufficient Air Pressure Check air pressure is as recommended will not start at the pump air inlet Air Filter Blocked Check if debris has clogged the inlet fil- ter on the FRL unit/pump inlet air valve ( some models have air filter on the air...
  • Page 8: Maintenance

    Follow the instructions clearly in “Disassembly and Reassembly” of the pump and in the troubleshooting section. Use genuine Teryair spares and if possible mention the serial number of the pump when ordering spares. Always replace elastomers as a set, eg diaphragms, balls and seats.
  • Page 9 Operation and Maintenance Guide ADPB 12 Plastic Pump Series Page 9 2) Replacement of primary Shaft O rings For changing the seals (20) first follow the step a, b, c & d from the diaphragm replacement. Remove the shaft assembly from the other side.
  • Page 10: Bill Of Materials For Adpb12Ppt Pumps

    Operation and Maintenance Guide ADPB 12 Plastic Pump Series Page 10 Bill of Materials for ADPB12PPT Pumps ITEM NO. PART NUMBER DESCRIPTION Repair kit- A.V.repacement kit- 1739702 1799703 173 08 09 Shaft Housing With Bush 173 08 06 Outer chamber...
  • Page 11: Exploded View For Adpb12Ppt Pump

    Operation and Maintenance Guide ADPB 12 Plastic Pump Series Page 11 Exploded View for ADPB12PPT Pump FF-MM-337-REV - 03...
  • Page 12: Dimensional Data

    Operation and Maintenance Guide ADPB 12 Plastic Pump Series Page 12 Dimensional Data ADPB12PPT FF-MM-337-REV - 03...
  • Page 13: Eu Declaration Of Conformity

    Is in conformity with the provisions of the following European Directives: (2006/42/EC) Machinery Safety and Har- monized standards ISO 12100-1: 2010: Safety of Machinery –general Principles for Design –Risk Assessment and Risk Reduction. Registered Office TERYAIR EQUIPMENT PVT. LTD. A-1, Tirupati Udyog Nagar, Sativali Road, Vasai(E), Palghar – 401 208. Maharashtra, India Web site www.teryair.com...
  • Page 14: Warranty Certificate

    Teryair products or components. Dealer/End User shall have no right or remedy and Teryair shall have no liability or obligation under the warranty, if: (i) a Product is altered, changed, modified or tampered with in any way, (ii) a Product is damaged after deposit with the transporter for shipment; (iii) a Product is not properly preserved, packaged, stored, processed or handled after receipt;...
  • Page 15 Operation and Maintenance Guide ADPB 12 Plastic Pump Series Page 15 This page is intentionally Left blank. FF-MM-337-REV - 03...

Table of Contents