Read this manual carefully before installing, operating or servicing this equipment. It's the responsi-
bility of the employer to ensure this manual is read by the operator. Please preserve this manual.
This document is issued with Product Serial No
Operation and Maintenance Guide
ADPB 25 PPX
Descriptions
Polypropylene with PTFE fitments
Polypropylene with Santoprene fitments

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ADPB 25 PP Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Teryair ADPB 25 PP Series

  • Page 1 Operation and Maintenance Guide ADPB 25 PPX Models Descriptions ADPB25PPT/R/P/G Polypropylene with PTFE fitments ADPB25PPS/R/P/G Polypropylene with Santoprene fitments Read this manual carefully before installing, operating or servicing this equipment. It’s the responsi- bility of the employer to ensure this manual is read by the operator. Please preserve this manual. This document is issued with Product Serial No...
  • Page 2: Table Of Contents

    Operation and Maintenance Guide ADPB 25 Plastic Pump Series Page 2 Table of Contents Pump Nomenclature Operating and Safety instructions Operating Instructions Suggested site selection and installation recommendations Troubleshooting Maintenance Diassembly and Re-assembly Bill of Materials for ADPB 25 PPTR Pump Bill of Materials for ADPB 25 PPSR Pump Exploded View for ADPB 25 Pumps Dimensional Data...
  • Page 3: Pump Nomenclature

    Operation and Maintenance Guide ADPB 25 Plastic Pump Series Page 3 Pump Nomenclature Air Valve Type Pump Size Material of Construction Material of Bolted or Threading on Inlet Diaphragm Clamped and Outlet 06 - 1/4” 12 - 1/2” 15 - 1/2” DP - Classic AL - Aluminium R- NPT...
  • Page 4: Operating Instructions

    Operating Instructions The Teryair diaphragm pump generates a alternate stroking of the diaphragms against the fluid in the liquid chambers of the Pump. This reciprocatory action is responsible for the fluid being pumped.
  • Page 5: Suggested Site Selection And Installation Recommendations

    Operation and Maintenance Guide ADPB 25 Plastic Pump Series Page 5 Caution: Temperature limitations and diaphragm options Excellent choice when pumping highly aggressive fluids such as aromatic or chlorinated hydrocarbons, PTFE acids, caustics, ketones and acetates. Temperature range +4°C to +104°C (+40°F to +220°F) Suggested Lubricants Brand Above 27 Deg C (...
  • Page 6 Operation and Maintenance Guide ADPB 25 Plastic Pump Series Page 6 Location selection Suction Pump location must be easily accessible with reasonable Ensure that the suction head after installation is well space around for maintenance operations. within the pumps suction capabilities Pump dimensional data for each variant is available in section showing exploded views Muffler...
  • Page 7: Troubleshooting

    Operation and Maintenance Guide ADPB 25 Plastic Pump Series Page 7 Troubleshooting Serial No Description Causes Remedial Action Pump stops and Insufficient Air Pressure Check air pressure is as recommended will not start at the pump air inlet Air Filter Blocked Check if debris has clogged the inlet fil- ter on the FRL unit/pump inlet air valve ( some models have air filter on the air...
  • Page 8: Maintenance

    Follow the instructions clearly in “Disassembly and Reassembly” of the pump and in the troubleshooting section. Use genuine Teryair spares and if possible mention the serial number of the pump when ordering spares. Always replace elastomers as a set, eg diaphragms, balls and seats.
  • Page 9 Operation and Maintenance Guide ADPB 25 Plastic Pump Series Page 9 Now we can remove the end support Replacement of Primary (32), spacer (8) and orings (31). Examine for Shaft & seals wear and replace the same. Follow the procedure a,b & c of dia- Now assemble in reverse manner as phragm replacement and thereafter we can per exploded view.
  • Page 10: Bill Of Materials For Adpb 25 Pptr Pump

    Operation and Maintenance Guide ADPB 25 Plastic Pump Series Page 10 Bill of Materials for ADPB 25 PPTR Pump Illu Part Illu Part Description Description Number Number Combined Shaft 6129004S Hex. Nut 6124019 Housing 6129003S Hex Bolt 6120805 Outer Chamber Side 6125134 External Circlip 6123009...
  • Page 11: Bill Of Materials For Adpb 25 Ppsr Pump

    Operation and Maintenance Guide ADPB 25 Plastic Pump Series Page 11 Bill of Materials for ADPB 25 PPSR Pump Illu Part Illu Part Description Description Number Number Combined Shaft 6129004S Hex. Nut 6124019 Housing 6129003S Hex Bolt 6120805 Outer Chamber Side 6125134 External Circlip 6123009...
  • Page 12: Exploded View For Adpb 25 Pumps

    Operation and Maintenance Guide ADPB 25 Plastic Pump Series Page 12 Exploded View for ADPB 25 Pumps FF-MM-405-REV - 01...
  • Page 13 Operation and Maintenance Guide ADPB 25 Plastic Pump Series Page 13 Exploded View A & B for ADPB 25 Pumps A- OUTLET ASSEMBLY B- INLET ASSEMBLY FF-MM-405-REV - 01...
  • Page 14: Dimensional Data

    Operation and Maintenance Guide ADPB 25 Plastic Pump Series Page 14 Dimensional Data 1/4" NPT 1" NPT AIR INLET FLUID OUTLET 1/2" BSPP AIR EXAUST 1" NPT FLUID INLET 1" ANSI FLANGE 8.50 198.5 ADPB 25 PPT/S FF-MM-405-REV - 01...
  • Page 15 Operation and Maintenance Guide ADPB 25 Plastic Pump Series Page 15 Repair and Replacement Kits ADPB25 Series Illu. No. Part No. Description 6124026 Gasket 2586050 Bonded Diaphragm 2584150S Diaphragm (Santoprene) 6120803 Ball Seat 1603615T Valve Balls 6124032 O' Ring 6124031 O' Ring 6124030 Seals For Air Valve...
  • Page 16: Eu Declaration Of Conformity

    Palghar – 401208, Maharashtra, India. CE certification registration no – C E 16832 Issued by – BMQR Certifications Pvt Ltd. www.cemarking-india.com Valid Till – 03/11/2021 Signed for and on behalf of TERYAIR EQUIPMENT PVT. LTD. Place of Issue: Date: FF-MM-405-REV - 01...
  • Page 17: Warranty Certificate

    Teryair products or components. Dealer/End User shall have no right or remedy and Teryair shall have no liability or obligation under the warranty, if: (i) a Product is altered, changed, modified or tampered with in any way, (ii) a Product is damaged after deposit with the transporter for shipment; (iii) a Product is not properly preserved, packaged, stored, processed or handled after receipt;...
  • Page 18 Operation and Maintenance Guide ADPB 25 Plastic Pump Series Page 18 This page is intentionally Left blank. FF-MM-405-REV - 01...